14. Electrical setup
1. Always check that the circuit breaker in the electrical panel is in the
OFF position, and that all high voltage circuits (more than 42.4V)
are completely isolated from the mains supply before doing any
work. The pole must be raised before isolating system.
2. Ensure that all low voltage systems (less than 42.4V) are suitably
protected from damage, by disconnecting all sources of power such
as chargers and batteries before doing any work.
3. All electrical work must be carried out according to the
requirements of all applicable local electrical codes. (It is
recommended that a licensed electrical contractor perform such
work).
Page 30
Connect all wiring
1. Connect all cables as required for the specific installation.
2. Ensure all interconnecting cables are securely in place.
3. Ensure single phase mains power is connected to the system.
4.
Switch on the mains (isolator and circuit breaker), make sure that the battery is
connected and check that the polarity is correct.
The wiring diagrams on page 11 begin connection at the
termination board
,
and
not
the controller
SECTOR
controller
Free-exit
loop detector
base
SECTOR
termination board
incorporating FLUX OB
FIGURE 36. ELECTRONICS ASSEMBLY