Page 32
Option 1
All connections are made to the termination board and NOT the
controller
(Refer to page 8)
The different inputs to and outputs from the termination board, react according
to the following when
Simplex Mode
is selected:
!
MI:
In this mode, the memory input acts simply to raise and lower the boom
pole with sequential activations
!
Lower:
A dedicated input to only lower the boom pole
!
Raise:
A dedicated input to only raise the boom pole
!
TVI:
Potential-free contact that can be used for a courtesy or security light.
The light illuminates when the barrier is operated and remains switched on for
an adjustable period of time after the boom pole has lowered
!
Close (closing loop):
The FLUX OB onboard loop detector can be used or a
closing loop detector must be fitted. In addition to sensing when the vehicle
has passed the barrier for closing purposes, it will act as a safety loop
preventing the boom pole from being lowered onto a vehicle present on the
loop