Page 45
!
Partly open indication Opening indication
!
Closing indication
!
Partly closed indication
!
Closed indication
!
Pedestrian indication
!
Unknown indication
An example of where the External Gate Status Indication will typically be used
is where two D-Series operators have been connected for interlocking
purposes, i.e. one cannot be operated while the other one is in motion. In
such a case, the XIO of one operator will be connected to LCK of the other, XIO
set as the desired indication, and the indication set to be ON only for a CLOSED
status. Since LCK is a normally-closed circuit, when Operator 1 is triggered it
will break the circuit and invoke Holiday Lockout in Operator 2; when Operator
1 then reaches the closed position again (since XIO has been configured to be
active for CLOSED only), the circuit will be completed and Operator 2 will be
allowed to operate.
Menu 3 - Autolower
!
!
Autolower Status
If enabled, the boom pole will automatically lower after a preset
Autolower
time
Autolower Time
The
Autolower
time can be set anywhere from 1 to 240 seconds (four minutes)
!
Autolower Override
Temporarily turn off Autolower. Activate and maintain the memory input for
longer than the Autolower Override Time. Activate Memory input to clear the
override.
!
Autolower Advanced Options
Set the conditions under which the boom pole will automatically lower. More than
one condition can be selected:
!
Autolower on Raised -
automatically lower the boom if boom pole is fully
raised
!
Autolower on Partly Raised -
automatically lower the boom pole if it has
been stopped partially raised
!
Autolower on Partly Lowered -
automatically lower the boom pole if it has
been stopped partially lowered