** Performance may vary depending on actual home operating conditions.
Spring Handle
Twist spring handle in a counter
clockwise motion while pushing on the handle
will "thread" down to desired location
14
O
PE
N
CL
O
SE
Model Series
Desired Burn Rate
Inlet Air Setting
**
Approximate
BTU Output
Low
Fully closed
10,467
Medium Low
1/4” (6mm) open
12,118
Medium High
1/2” (13mm) open
19,413
CJW1000
High
Fully open
26,100
Low
Fully closed
10,370
Medium Low
1/8” (3mm) open
12,420
Medium High
1-3/8” (35mm) open
15,676
CJW1500
High
Fully open
29,301
Low
Fully closed
12,000
Medium Low
1/8” (3mm) open
13,400
Medium High
1/4” (6mm) open
17,700
CJW2000
High
Fully open
55,100
SPRING HANDLE ASSEMBLY
AIR CONTROL SETTINGS
Door Spring Handle
P/N S11007
Air Control- Spring Handle
P/N S11008
Decorative Brass trim
Remove protective plastic coating from Decorative Brass Trim before operating your wood heater.
Brass Body Trim
P/N S32217- CJW1000 series
P/N S32098- CJW1500 series
P/N S32592- CJW2000 series
Brass Ash
Fender Trim
P/N S32023- CJW1000 series
P/N S32075- CJW1500 series
P/N S32593- CJW2000 series