Century FW3300 Installation and Operation Manual
7
2 General Information
2.1
Century FW3300 Specifications
Fuel Type
Cordwood
Test Standards (safety)
ULC S627 and UL 1482
Test Standard (emissions)
EPA Method 28 (40 CFR Part 60)
Heating capacity range*
1050 to 2000 sq. ft. (98 to 186 m
2
)
Maximum heat output**
(EPA test fuel)
29 400 BTU/h (8.6 kW/h)
Maximum heat output**
(natural hardwood fuel)
80 000 BTU/h (23.4 kW/h)
Optimum efficiency
76 % (With blower installed)
Test Standard (efficiency)
CSA B415.1
Approximate Burn Time
6 to 8 hours
Shipping Weight
441 lb (200 kg)
Firebox Volume
2.5 cu.ft. (0.071 m
3
)
Maximum Log Length
17" north-south***
Flue Outlet Diameter:
6" (150 mm) diameter (vertical)
Baffle Material
Vermiculite
* Burn time and heating capacity may vary subject to location in home, chimney draft,
chimney diameter, locality, heat loss factors, climate, fuels and other variables.
** The EPA test fuel is dimensional Douglas fir pieces stapled together into cribs with air
spaces between. We also test using the same procedure except using split hardwood
firewood to reflect real-world heat output. This stove is not intended to operate at its peak
heat output continuously.
*** East-west: through the door you see the sides of the logs; north-south: through the door
you see the ends of the logs.