A-14
DIP switches setting
PV037-LSK/PV057/PV058 DIP Switches setting
SW1
System Menu
ON
No t d i s p l a y s ys te m m e n u , g o to ON-L INE c o m m u n i c a ti o n a fte r
tu rn s o n .
OFF
Di s p l a y s ys te m m e n u wh e n tu rn s o n . No t g o to ON-L INE
c o m m u n i c a ti o n .
SW2
Em e rg e n c y re c o ve ry th e HMI BIOS to d e fa u l t va l u e .
ON
Se t to d e fa u l t OS ve rs i o n o r c u s to m i ze d OS ve rs i o n .
OFF
Se t to d e fa u l t BIOS ve rs i o n B.
SW3
SW4
HMI operation mode (Supports special functions for customized BIOS
version)
OFF
OFF
Re s e rve d
ON
OFF
To e xe c u te HMI Co m m u n i c a ti o n te s ti n g p ro g ra m (SW 1 ,2 m u s t
s e t to Off)
OFF
ON
To e xe c u te Ke y a d j u s tm e n t p ro g ra m o r To u c h a d j u s tm e n t
p ro g ra m (SW 1 ,2 m u s t s e t to Off)
ON
ON
To e xe c u te HMI a p p l i c a ti o n p ro g ra m
SW5
Re s e rve d
ON
Re s e rve d
OFF
Re s e rve d
SW6
Re s e rve d
ON
Re s e rve d
OFF
Re s e rve d
6
5
4
3
2
1
***The PV037/PV057 has a BIOS password recovery system to prevent damage when
missing password. When you forget the password, which has been set to the HMI, this
HMI can execute RUN AP/Calibrate operation but cannot execute BIOS/Download
AP/Clear SRAM operations. When the users want to download new AP without
password, please set all DIP switches to off (SW1-6=Off), When turns on HMI again,
the HMI will display the clean all AP and old password screen. After proceeding this
procedure, the HMI can be operated normally again.
For some models of the PL037-LSK/PL037-LST/PV037-LNT/PL035-TST/PV035-
TST/PV035-TNT/GD057-LST/GD058-TST there are no dip switch.