background image

LTO Autoloader Barcode Reader

 

Volume Identifier Formats  

The volume identifier only uses ASCII characters A through Z (41h-5Ah), 0 through 9 
(30h-39h), and the combinations of “CLN” and “DG {space} ” as described below.  

The prefix “CLNvnnL1”is reserved for cleaning cartridges. The “v” field is an 
alphanumeric field to identify a drive unique cleaning cartridge. The “nn” alphanumeric 
field is used to track individual cleaning cartridge activity (for example, usage and life). 
When the drive requires cleaning, it will request loading of the unique type cleaner 
cartridge.  

Diagnostic/Service cartridges use the prefix “DG{ space} vnnL1”. The “v” field is an 
alphanumeric field to identify a drive-unique diagnostic cartridge, if required. The “nn” 
alphanumeric field identifies a specific diagnostic cartridge volume.  

The volume identifier field consists of six left-justified alphanumeric characters as 
specified in SCSI-3 Medium Changer Commands (SMC) ANSI NCITS 314-199X.  

The media identifier characters “Lg” are controlled characters. The “L” designates the 
LTO Ultrium type of cartridge. The next character “g” (alphanumeric) designates the 
generation of the LTO Ultrium cartridge. 

 

Reading area 

 
Due to mechanical tolerances the barcode reader will read in a defined area with a height of 5,15 
mm (see figure below). This area must contain barcode information only and should not contain 
any character information. 
 

 

 

Label Orientation on Cartridge 

 

 

8

 

Summary of Contents for LTO Autoloader

Page 1: ...LTO Autoloader Barcode Reader Installation Guide Part Number 10010534 001 April 2003 Rev B January 2004 Copyright 2004 Certance LLC All rights reserved ...

Page 2: ...de Reader 4 Barcode labels 4 Removing the Barcode Reader 4 Bar Code Label Specification 5 About this Specification 5 Symbology 5 Bar Code Characters 5 Encodation 5 Quiet Zone 5 Optical Specification 6 Label Dimensions 6 Volume Identifier Formats 8 Reading area 8 Label Orientation on Cartridge 8 2 ...

Page 3: ...SCSI cable s and power cord from the rear panel of the autoloader and disconnect the power cord from the outlet 4 Remove the cover plate from the rear panel and save the screws Store the cover plate you may use this plate later if you remove the barcode reader 5 Orient the barcode reader in front of the slot There is only one correct position Check to make sure that the holes align 6 Connect the c...

Page 4: ...code reader can only operate if barcode labels are present on the tape cartridges Make sure that only labels complying with the appropriate barcode label specification are used see section below Removing the Barcode Reader 1 Power down the autoloader 2 Remove the SCSI cable s and power cable from the rear panel Then disconnect the power cable from the outlet 3 Remove the screws that attach the bar...

Page 5: ...ter eight alphanumeric characters and the stop character Quiet zones precede and follow the start and stop characters The first six characters may be any combination of upper case A through Z or 0 through 9 for example ABC123 to identify the cartridge volume The last two characters are determined by the LTO Ultrium cartridge media type for example L for LTO Ultrium and 1 for tape cartridge generat...

Page 6: ...closer to each other than 0 01 inches 0 254 mm The reflectivity of the black areas RB may be measured anywhere within any black area on the bar code The print contrast signal PCS is defined as RW RB RW and is measured using the Mcbeth PCMII print contrast meter PCS must be a minimum of 0 85 Using the PCS measurement will avoid isolated print defects and edge roughness A void is an area within a bl...

Page 7: ... character Edge roughnessa 0 0015 inches 0 038 mm maximum Tolerances 0 XXX 0 005 inches 0 XX 0 03 inches 0 XXX 0 127 mm 0 XX 0 762 mm Variation between all wide bars white and black Less than 0 0015 inches 0 0381 mm Variation between all narrow bars white and black Less than 0 0015 inches 0 0381 mm Print side Print the bar code string on the label so it is on the side of the label towards the hub ...

Page 8: ...ace vnnL1 The v field is an alphanumeric field to identify a drive unique diagnostic cartridge if required The nn alphanumeric field identifies a specific diagnostic cartridge volume The volume identifier field consists of six left justified alphanumeric characters as specified in SCSI 3 Medium Changer Commands SMC ANSI NCITS 314 199X The media identifier characters Lg are controlled characters Th...

Reviews: