11
MB Pool & spa heater
185, 265 & 405 Models
FLUE TERMINAL (Indoor) Draught Diverter
Illustration
1. Remove the louvred jacket top by removing
four (4) No.10 fl at head screws.
2. If originally installed, remove "Pagoda" top
from the louvered jacket top.
3. Place the inner stack adapter panel over the
fl ue collector inside the heater. Make sure
the
fl anged side of the fl ue opening is up.
4. Turn the stack (diverter) upside down and set it
down bottom side up.
5. Turn the jacket top panel (removed in step 1)
down and place it through the stack.
6. Attach the three (3) mounting brackets to the
stack using the screws provided and the holes
that are pre-drilled in the stack.
Make sure the
brackets are positioned with the fl ange near
the top side of the stack (see illustration
below).
Caution must be taken not to over tighten and
strip the screw threads.
7. Turn the assembled stack and jacket top, right
side up. The jacket top will be trapped
between the brackets and the top of the stack.
Place the stack over the inner adapter panel
fl anged hole and lower the louvered jacket top
panel back into its original position. Reinstall
the four No.10 fl at head screws removed in
step 1 above.
S8960
Draught
Diverter
Jacket
Top
Mounting
Screws (8)
Screw Hole
Location
3.25"
82.5mm
Draught
Diverter
No.10 Screw (3)
Flue Collector
(Part of Heater)
Inner Stack
Adapter Panel
Jacket Top Panel
(Part of Heater)
Mounting Bracket (3)
INDOOR HEATER
The design is also certifi ed by Advantica for indoor
installation when fi tted with the appropriate draught
diverter and a suitable fl ue system to outside. Note
that the heater must be in a room separated from liv-
ing rooms and provided with appropriate ventilation
direct to the outside.
055 Models
FLUE TERMINAL (Indoor) Draught Diverter
Illustration
Locate and assemble as shown. Secure with screws
supplied in envelope inside carton.
105 & 155 Models
FLUE TERMINAL (Indoor) Draught Diverter
Illustration
Locate and assemble as shown. Secure with screws
supplied in envelope inside carton.
Draught
Diverter
Mounting
Screws