Fig. 7:2d
27
100 Gas Condensing Pool Heater
20/10/03
100W
Is 230V at L connection ?
Correct Mains Supply.
NO
Is there 230V to the pump
on its PCB terminals ?
Is the 2A PCB fuse OK ?
NO
Replace 2A PCB fuse.
NO
Are the micro-switches
operating electrically.
YES
NO
Replace the micro-
switch assembly.
Replace the main PCB
YES
Does the Fan start ?
Is the Pump free to rotate ?
Free or replace Pump
NO
YES
Does the pump start ?
NO
YES
Has the O/H cutout tripped ?
Is there 230V to the Fan ?
NO
NO
NO
Has the Flue Stat tripped ?
NO
YES
YES
Reset or replace.
Reset or replace.
YES
Replace Fan.
Is there 230V from the CVI
Replace CVI board.
NO
YES
YES
Does the Burner light ?
FAULT FINDING Pool or Space Heating Operation
Is the Gas Inlet
pressure 20 mb
NO
Provide adequate Gas Supply
Replace CVI board, problem solved ?
if not replace CVI Valve
YES
Does Spark stop after Ignition ?
NO
YES
YES
Are the HT Lead & Electrode OK ?
Replace Electrode and Lead
NO
YES
Replace CVI board.
Is polarity of Boiler supply OK ?
NO
YES
Correct
Does Burner Flame increase to Maximum ?
Does the Flame reduce as temperature rises to Maximum ?
Does the Flame reduce with the Boiler Thermostat ?
Does the Flame stop before the O/H trips ?
YES
YES
YES
YES
Is the Thermistor reading
correct to Table A. ?
NO
NO
NO
NO
Replace Thermistor
NO
YES
Replace Main Board.
BOILER OPERATION SATISFACTORY
Is there upto 165mA on yellow lead to coil ?
NO
Start with system and boiler cold, with the power ON and no Hot Water taps open.
Set the system controls to call for heat.
0
20
10
30
40
50
60
70
80
90
33118
20198
12676
8176
5406
3657
2526
1780
1277
931
Temp C
Ohms
TABLE A
YES
Is there a spark ?
Are the HT Lead & Electrode OK ?
Has the Pressure
Switch operated.
NO
NO
NO
Is there a blockage in the
Condensate Trap or tubes ?
Replace Electrode and Lead
Replace the CVI board.
NO
YES
Replace the Pressure Switch.
YES
YES
NO
Has the Pilot lit ?
Check Pilot Injector, clean or replace.
NO
YES
( CVI = Combined Valve & Ignition )
YES
Replace CVI
Replace Modulating Coil, now OK ?