background image

6

List of supplied components

•  PU2 LED Light incl 20m cable pre-wired
•  2 x o-rings (fitted) for Class C 1

1

/

2

” pipe fitting (PU2MLP & PU2MLPW only)

•  2 x o-rings (bagged) for Class C 50mm pipe fitting (PU2MLP & PU2MLPW only)
•  Information for use document

Installation

WARNING

  This equipment must be installed by qualified persons only. Improper installation can create 

electrical hazards which could result in property damage, serious injury or death. Improper installation and 
servicing will void the warranty.

WARNING

  A qualified electrician must carry out all electrical wiring in accordance with local electrical 

regulations.

For concrete pools – PU2MLP, PU2MLPW

This light is designed to be inserted into 1

1

/

2

” pipe which has been cut flush and sealed at the pool wall face. It is recommended that 

the receiving pipe/s be situated between 400-700mm below water level.

The receiving pipe should be extended/converted to conduit which then runs 

above

 the water level to create a run for the cable to 

the central control/power point.

When the light cable is fed through the receiving pipe/conduit, sufficient cable should remain free within the pipe in order to be able 
to remove the light unit to the pool surround.

Run the cable through the pipe/conduit back to the desired control/power point.

Coil the free cable into the pipe and insert the light body – the o-rings around the light will create a friction fit. The o-rings do not act as a 
watertight seal. 

The use of a suitable lubricant on the o-rings will make the insertion of the light into the pipe easier.

Multiple lights can be installed within a single pool.

7

For vinyl liner pools – PU2MLPL, PU2MLPWL

This light is designed to be installed into a Certikin liner inlet fitting connected to either 1

1

/

2

” or 2” pipe. It is recommended that the 

receiving fitting/s be situated between 400-700mm below water level.

NOTICE

  The inlet fitting should be for use by the light only – it should not be connected to the pool 

circulation system.

The liner fitting and the liner should be installed as normal. The light body is threaded and shaped in order to be a perfect fit into and 
over the liner inlet clamp plate.

The pipework connected to the inlet fitting/s should be extended/converted to conduit which then runs 

above

 the water level to 

create a run for the cable to the central control/power point.

When the light cable is fed through the receiving pipe/conduit, sufficient cable should remain free within the pipe in order to be able 
to remove the light unit to the pool surround.

Run the cable through the pipe/conduit back to the desired control/power point.

Coil the free cable into the pipe and insert the light body – position the light body within the inlet fitting and screw the light into 
place.  When fully installed the light body will cover the inlet clamp plate exactly.

Multiple lights can be installed within a single pool.

Summary of Contents for PU2MLP

Page 1: ...ocument must be read before the installation and start up of this product Once the product has been installed this document must be given to the owner operator of this equipment 01993 777200 info certikin co uk www certikin co uk Manufactured By Maysee Technology Ltd China Imported By Certikin International Ltd Witan Park Station Lane Industrial Estate Witney Oxfordshire OX28 4FJ FEBRUARY 2020 ...

Page 2: ...electrical wiring in accordance with local electrical regulations NOTICE Do not operate the light in a non wet environment for long periods DANGER This notice signifies an ELECTRICAL hazard with a HIGH level of risk which if not avoided WILL result in death or serious injury This notice signifies An ELECTRICAL hazard with a MEDIUM level of risk which if not avoided COULD result in death or serious...

Page 3: ...s of a threaded attachment into a new or existing Certikin liner inlet fitting RGBW units are designed to be operated and controlled by a separate Wi Fi controller driver unit and power supply W units are designed to be operated as an on off light from a separate power supply 10 Operation RGBW lights are operated via the control unit and or App provided with the Wi Fi 104 unit Please refer to thes...

Page 4: ...m RGB 450 500lm 1750 2000lm CRI Ra 85 Max Life Time 50 000H Housing Material 316 Stainless Steel Cover Material Tempered Glass Working Temperature 20 C 50 C IP Grade IP68 Mounting Type Push fit into Class C 1 5 pipe alternative o rings included for fit into Class C 50mm pipe Cable Length 20m Coverage 8m2 9 White W lights White lights operate as a simple switch power on off only however multiple li...

Page 5: ...able Length 20m Coverage 8m2 NOTICE This product contains no serviceable or changeable parts Do not attempt to open the light housing Opening the light housing will void all warranty Once expired this product should not be disposed of via general waste but through a regulated waste disposal and recycling centre please consult your local authority for full advice 8 RGBW lights Each RGBW light requi...

Page 6: ... body the o rings around the light will create a friction fit The o rings do not act as a watertight seal The use of a suitable lubricant on the o rings will make the insertion of the light into the pipe easier Multiple lights can be installed within a single pool 7 For vinyl liner pools PU2MLPL PU2MLPWL This light is designed to be installed into a Certikin liner inlet fitting connected to either...

Reviews: