background image

2019 Cervis, Inc.  

 

8.0. 

SmaRT BU-xH6R Base Unit 

Manual 

 U078.2.3-SmaRTxH6R_BU-R 

™ 

™ 

Summary of Contents for SmaRT BU-xH6R

Page 1: ...2019 Cervis Inc 8 0 SmaRT BU xH6R Base Unit Manual U078 2 3 SmaRTxH6R_BU R...

Page 2: ...iled information This product may be returnable to the distributor for recycling Contact your distributor for details Industry Canada Statement This device complies with Canadian RSS 210 The installer...

Page 3: ...ation Output Check Operating Mode Interlock 7 2 0 SmaRT BU xH6R Specifications 9 3 0 SmaRT BU xH6R Variations 10 4 0 BU xH6R Troubleshooting Hints 12 5 0 BU xH6R BU xH6R EXT Antenna and Cable List 14...

Page 4: ...ns 15 Figure 9 Associate Dissociate Buttons 16 Figure 10 Associate and Dissociate Switch Actuations 18 Figure 11 MCB Switch Actuation for Associate and Dissociate 21 Figure 12 PG Switch Actuation for...

Page 5: ...6R Base unit with six relay outputs controlled by a SmaRT handheld remote Each SmaRT BU xH6R can communicate with up to eight handhelds SmaRT 9nn or 2nn Remote Control System SmaRT system consisting o...

Page 6: ...sure that the machinery and surrounding area is clear before operating Do not activate the remote control system until certain that it is safe to do so Remove power from the base unit before attempti...

Page 7: ...ge of 100 240VAC 47 440Hz or 120 370VDC The HVU power option uses a universal converter that can accept either high voltage AC or DC input The converter is not polarity sensitive BU xH6R xxx LVD accep...

Page 8: ...2 4 GHz 100 mW radio frequency RF power CAN interface optional Internal antenna standard external antenna optional 300m 1000ft range Six independent relay outputs each with a single Form C contact 8A...

Page 9: ...he wiring harness cables are on hand Always mount the receiver away from any intense radio or electric disturbance sources Make sure the mount is secure Mount the unit where you have enough room for y...

Page 10: ...2 3 SmaRTxH6R_BU R 4 Figure 3 2 4GHz and 900MHz External Antenna Mounting Dimensions 7 4mm 0 29 dia 133mm 5 25 74 9mm 2 95 36mm 1 4 180mm 7 08 900MHz 183mm 7 2 2 4GHz 115mm 4 57 42 69mm 1 68 42 69mm 1...

Page 11: ...enna Extension Kit Installation Make sure the antenna is located in clear line of sight of the remote 1 Loosen and remove extension cable nut to allow the antenna ferrule to push through a mounting ho...

Page 12: ...tage drops below minimum input volts for a consistent period of time the LEDs including the TX RX LEDs if transceiving will dim and flicker These circumstances are symptoms of a battery or power sourc...

Page 13: ...e 4 AC Sup The NOS option can be specified to omit them However this can leave the contacts vulnerable to switching transients and arcing Contact Cervis Inc Customer Service for assistance in choosing...

Page 14: ...ate Output K5 Output K5 active Output LED lights and remains lit until the PTO Output 5 is released Press and hold function corresponding Output 6 Activate Output K6 Output K6 active Output LED lights...

Page 15: ...acceleration 10 0g peak shock acceleration Radio Frequency 906 924MHz 2405 2480MHz License No license required Modulation DSSS Antenna Internal Enclosure Dimensions mm 133 x 118 x 36 inch 5 24 x 4 65...

Page 16: ...U 9H6R EXT LVA NOS 900MHz 10mW 7 28VAC External RS 232 No Yes BU 9H6R EXT LVA NOS CAN 900MHz 10mW 7 28VAC External CAN No No BU 9H6R EXT HVU 900MHz 10mW 100 240VAC External RS 232 Yes Yes BU 9H6R EXT...

Page 17: ...A NOS CAN 2 4GHz 100mW 7 28VAC External CAN No No BU 2H6R EXT HVU 2 4GHz 100mW 100 240VAC External RS 232 Yes Yes BU 2H6R EXT HVU CAN 2 4GHz 100mW 100 240VAC External CAN Yes No BU 2H6R EXT HVU NOS 2...

Page 18: ...power to let it cool down Restart after 15 minutes If problem persists contact Cervis Inc service department Out LED not active Electrical signal not reaching the LED Are interlocked output buttons b...

Page 19: ...curs when pressing the handheld output control buttons Should a jerkiness of motion occur while constantly pressing an output button immediately stop operation Check the OUT LED and the other BU xH6R...

Page 20: ...t antenna extension cable J5 02 10 ft antenna extension cable J5 02 10 ft antenna cable J5 02 and external antenna BB3 06 EXT 10 900 3 ft antenna cable J5 07 and external antenna BB3 06 EXT 3 900 Note...

Page 21: ...before shipping when systems are ordered However it may be necessary to establish or re establish communication between a remote and a base unit at some point The Associate procedure does this In som...

Page 22: ...ht release B1 and B2 LEDs ER and BA light Note If you do not immediately within approximately 2 sec press the next button all LEDs flash and the Associate procedure is aborted You must then restart th...

Page 23: ...RX LEDs light steady 5 When LEDs TX and RX light release B1 and B2 LEDs ER and BA light Note If you do not press the next button within the two second interval all LEDs flash and the procedure is abo...

Page 24: ...r up the base unit while continuing to hold SW13 and SW12 When TX RX ERR and BAT light solid release SW13 and SW12 A successful association is indicated when LEDs TX and RX are rapidly blinking in uni...

Page 25: ...Base Unit 2019 Cervis Inc 19 Note Be aware that all remote associations to the base unit are now broken...

Page 26: ...ivating and using the console remote 1 Stand near the base unit with the remote OFF and power removed from the base unit disconnect the P1 and P2 cables or turn the source power OFF 2 Release the STOP...

Page 27: ...emote OFF and power removed from the base unit disconnect the P1 and P2 cables or turn the source power OFF 2 Release the STOP button on the MCB handheld by pulling it up 3 Push and hold switch SW1 DO...

Page 28: ...old switches SW1 and SW7 When all four LEDs light solid release switches SW1 and SW7 A successful association is indicated when LEDs TX and RX are rapidly blinking in unison Figure 12 PG Switch Actuat...

Page 29: ...button when the unit is ON or by allowing the unit to time out Off is indicated when none of the LEDs are active when any function button is pressed Safely power down the SmaRT base unit by disconnect...

Page 30: ...base unit disconnect the P1 and P2 cables or turn the source power OFF and turn off the handheld 2 Stand near the base unit with the handheld in a clear unobstructed line of sight 3 Press and hold but...

Page 31: ...Base Unit 2019 Cervis Inc 25 Visit our Web site at www cervisinc com 2019 Cervis Inc All rights reserved Content is subject to change without notice...

Reviews: