SmaRT Console Box Remote
©
2020 Cervis, Inc. 13
2.8.2 Minimum Adjustment
LED 8 on the standard base unit lights solid (see right), indicating lever or joystick select mode
(minimum).
1. To select the minimum activation of the lever or joystick to be adjusted, move the
desired switch beyond 50% deflection and release it back to neutral. LED 8 on the
standard base unit flashes, indicating Adjust Mode (min).
•
To retain the current minimum value, flip the Adjust switch (S14) UP.
•
To set the minimum to 0%, flip the Associate switch (S13) DOWN to store that value.
•
To adjust the current value, slowly move the switch again until machine movement is
initiated. Continue to hold in position, and flip the Associate switch (S13) DOWN to store
the value, then release the lever or joystick to neutral.
Note: To cancel adjustment of the lever or joystick and return to Select Mode
(minimum), allow the lever or joystick to return to neutral
– LED 8 on the base unit will
light solid.
2. LED 8 goes out and LED 7 lights solid after storing, indicating Select Mode
(maximum). Continue to Section 2.8.3 to set maximum lever or joystick activation.
2.8.3 Maximum Adjustment
LED 7 on the standard base unit lights solid (see right), indicating Select Mode (maximum).
1. To select the maximum activation of the lever or joystick to be adjusted, move the
desired lever or joystick beyond 50% deflection, and release it back to neutral. LED
7 on the standard base unit flashes, indicating Adjust Mode (max).
•
To retain the current minimum value, flip the Adjust switch (S14) UP.
•
To set the maximum value at one increment above the minimum value, flip the
Associate switch (S13) DOWN to store that value.
•
Or, to adjust, slowly move the lever or joystick again until machine movement is to the
desired point. Continue to hold in position and flip the Associate switch (S13) DOWN to
store the value, then release the lever or joystick to neutral.
Note
:
To cancel adjustment of the lever or joystick and return to Select Mode
(maximum), allow the lever or joystick to return to neutral
– LED 7 on the base unit will
light solid.
2. LED 7 goes out and LED 8 lights solid after storing, indicating a return to Select
Mode (minimum). Return to Section 2.8.2 to set minimum lever activation.
Note
:
Flipping the Associate switch (S13) DOWN and the Adjust switch (S14) UP
toggles between MIN and MAX while in Adjust Mode.