SmaRT Console Box Remote
U093.3.0
14
2.8.4 Enter Adjust Mode for Enlarged Base Unit (EBU) PWM Outputs
Figure 7. Enter Lever or Joystick Adjust Mode (EBU)
1. Release the Stop switch (twist-up or pull-up), and flip the ON/OFF switch (S12)
UP.
2. Enter Adjust Mode by holding the Adjust switch (S14) UP (first) and the
Associate switch (S13) DOWN while watching the EBU LEDs. Adjust Mode is
indicated when the top three LEDs 1, 2, and 3, begin flashing (Figure 7).
3. Release the Adjust switch (S14) and the Associate switch (S13). LEDs 1, 2, and
3 go out, and then LED 3 lights solid (Figure 7). This indicates that you are in
Adjust Mode.
Note
:
To abandon Adjustment Mode at any time, hold the Adjust and Associate
switches (S14 and S13) DOWN.
Caution!
Be aware of lever or joystick activation during this process. Base unit
outputs may be active or activated during the adjustment process.
2.8.5 Minimum Adjustment
LED 3 on the EBU lights solid (see left), indicating lever or joystick select mode (minimum).
1. To select the minimum activation of the lever or joystick to be adjusted, move the
desired lever or joystick beyond 50% deflection and release back to neutral. LED 3
on the EBU flashes, indicating Adjust Mode (Min).
•
To retain the current minimum value, flip the Adjust switch (S14) UP.
•
To set the minimum to 0%, flip the Associate switch (S13) DOWN to store that value.
•
To adjust the current value, slowly move the lever or joystick again until machine
movement is initiated. Continue to hold in position and flip the Associate switch (S13)
DOWN to store the value, then release the lever or joystick to neutral.
Note: To cancel adjustment of the lever or joystick and return to Select Mode (min),
allow the lever or joystick to return to neutral
– LED 3 on the EBU will light solid.
2. LED 3 will go out and LED 2 will light solid after storing, indicating Select Mode
(Max). Continue to Section 2.8.6 to set maximum lever or joystick activation.
2.8.6 Maximum Adjustment
LED 2 on the EBU will light solid (see left), indicating Select Mode (maximum).
1. To select the maximum activation of the lever or joystick to be adjusted, move the
desired switch beyond 50% deflection and release back to neutral. LED 2 on the
EBU flashes, indicating Adjust Mode (max).
•
To retain the current minimum value, flip the Adjust switch (S14) UP.
About
4-seconds
S12
S13
S14
After S14,
S13 release
S14 S13 S12