Warrior CB-xW Transmitters
U114.1.1
14
Note: If your transmitter does not have a keyswitch, skip to Step 2.
2. Flip the
STOP
switch UP.
Verify that there is a radio frequency link (the
RF
LED is blinking):
Note: Do not press the green HORN/START pushbutton to pull in the MLC relays.
3. Simultaneously hold the
SELECT and NEXT
switches DOWN, and press the
STOP
switch DOWN.
As soon as you press the
STOP
switch down, an internal five-minute timer begins counting
down on the receiver. You now have five minutes to associate the second transmitter (if
necessary). Use the standard Association procedure for the type of transmitter
you’re using.
(Section 1.0 or see appropriate manual.)
After five minutes
—or one attempt to associate the transmitter—the timer clears and the receiver
locks out again.
2.8
Clearing CB-xW Stored Receiver ID (Factory Reset)
The CB-xW transmitter stores its associated receiver ID in its internal memory. During instances
of severe interference
—or perhaps when troubleshooting—it may become necessary to break
the established communications link between the transmitter and the system receiver. This is
called
“clearing the stored ID” or “Factory Reset.”
To Clear the Stored Receiver ID (Factory Reset):
1. Turn the transmitter on. (See steps 1
–2 in Section 2.4).