background image

 

 

User Manual 

 

 

U129.0.0 

2.1 How to clear a transmitter memory of association 

 

You can erase the transmitters association with a receiver.  If this process is completed the 
transmitter will not work with any receivers until it is re-associated with a receiver using the 
process outlined above.  If a transmitter becomes damaged or you need to remove a transmitter 
from service, put it in storage or send it in for repair it is recommended that you complete this 
process.   

1: Follow start-up procedure steps 1, release STOP switch 

 

2: When the 

B LED

 is 

ON

 solid, simultaneously press and release the 

A/B Select and 

WARNING/START

 switches.   

 

The four LEDs will begin to ‘scroll’ from bottom to top (B, A, Battery, TX/RX) 

indicating you are now in the transmitters ‘Maintenance Mode’.   

Note

: If the B LED goes out before you press the buttons, restart the process 

 

 

3: Now simultaneously press and hold Hoist UP, Hoist Down.  While holding UP and DOWN 

         press Trolley Reverse and release all buttons.   

 

The four LEDs will go back to ‘scrolling’ from bottom to top (B, A, Battery, TX/RX) 

indicating you are now back in the transmitters ‘Maintenance Mode’.   

 

Press STOP to deactivate the transmitter.     

 

Of this process is completed correctly the transmitter will not work with any receiver.  You  

can confirm the process is completed by activating the transmitter and the TX/RX LED  

should come on SOLID indicating it has no associated receiver in memory.  If the TX/RX  

LED begins blinking the process was not preformed correctly and the transmitter remains  

associated to a receiver, repeat the process.     

 

If at any time during the process you become unsure of the activity you are  

seeing press the STOP switch, remove the battery and contact the factory  

for support.   

 

 

   

  

 

 

 

Summary of Contents for Warrior ETHOS HHMS-9XW08-ND

Page 1: ...2020 Cervis Inc ETHOS HHMS 9XW08 ND Model Transmitter Manual...

Page 2: ...code 6 health canada radiofrequency exposure guidelines environmental workplace health health canada html Industry Canada Statement This device complies with Industry Canada licence exempt RSS standa...

Page 3: ...r 6 2 1 Celaring a transmitters memory Error Bookmark not defined 3 0 Transmitter Specifications 10 Appendix A Exposure to Radio Frequency Energy 11 Appendix B RF Exposure Considerations 11 Appendix C...

Page 4: ...mote control system until certain that it is safe to do so Turn off the transmitter and disconnect power from the receiver before attempting any maintenance This will prevent accidental operation of t...

Page 5: ...sion IEC standard 60529 The unit has four diagnostic LEDs that indicate radio frequency RF transmit receive Battery status and A selection and B selection Frequency Channel Hopping Direct Sequence Spr...

Page 6: ...Indication Meaning 1 Radio Frequency RF ON Transmitter searching for receiver or a button is being pressed Flashing Transmitting and receiving messages communicating with a receiver If a lag is occur...

Page 7: ...into the transmitter body until you hear a click Note Make sure the battery contacts are positioned relative to the front right side of the transmitter To charge the battery pack 1 Pinch the clamps o...

Page 8: ...ack The LED continues to flash until the voltage level drops to 6 1V when Auto Shutdown occurs Note The receiver LED quickly flashes three times once per minute when transmitter low battery is indicat...

Page 9: ...or main contactor closes Note If the Radio TX RX LED is on solid once you release the STOP switch the handheld may not be associated to a receiver or the receiver it is associated to may not have powe...

Page 10: ...refer to section 2 1 Note Before attempting association make sure that receiver S01 DIP Switch 8 in the desired receiver is set to the ON 1 position 1 Follow start up procedure steps 1 release STOP s...

Page 11: ...T switch make the selection If this is not the desired receiver continue to press and release the A B Select until the desired receiver is indicating it can be selected Again once the desired receiver...

Page 12: ...e Mode Note If the B LED goes out before you press the buttons restart the process 3 Now simultaneously press and hold Hoist UP Hoist Down While holding UP and DOWN press Trolley Reverse and release a...

Page 13: ...ETHOS Model Transmitter 2020 Cervis Inc 9...

Page 14: ...to 60 C Storage Temp 22 F to 158 F 20 C to 70 C Humidity 0 95 non condensing Radio Frequency 904 926 MHz 100mW License No license required Modulation DSSS Antenna Internal Enclosure Dimensions 76 2mm...

Page 15: ...r a belt or harness on the torso Equipment containing the radio module was evaluated for RF exposure hazards by two approaches 1 Maximum Permissible Exposure MPE for mobile applications 2 Specific Abs...

Page 16: ...User Manual U129 0 0 12 Appendix C Agency Identification Label Locations Figure 5 Agency Identification Label Locations...

Page 17: ...ETHOS Model Transmitter 2020 Cervis Inc 13 Visit our Web site at www cervisinc com 2019 Cervis Inc All rights reserved Content is subject to change without notice...