U100.5.0
12
Table 6. DIP Switch 4: Applies to HH, Only Applies to Mode 00 or 01
Name
Set Definition
AB CYC/IND
0
HH: Button 9 cycles A/B (See AB BOTH/OFF).
MCB: No effect.
1
HH: Button 9 activates A, button 10 activates B, NO AUX (see AB MOM/LAT)
MCB: No effect.
Table 7. DIP Switch 5: Only Applies to HH AND Only Applies to HH in Mode 00 or 01 and Only
Applies if AB CYC/IND = 1
Name
Set Definition
AB MOM/LAT
0
HH: A and B are momentary outputs.
MCB: No effect.
1
HH: A and B are latching outputs.
MCB: No effect.
Table 8. DIP Switch 6: Only Applies in Mode 00 (HH: AB CYC/IND Needs Set to 0)
Name
Set Definition
AUX MOM/LAT
0
HH: AUX is momentary.
MCB: AUX is momentary.
1
HH: AUX is latching.
MCB: AUX is latching.
Table 9. DIP Switch 8: Applies to HH, Only Applies in Mode 00 or 01
Name
Set Definition
ASOC LOCK
0
Association NOT permitted.
1
Association permitted.
Note: DIP switches may be changed at any time. However, changes will only be applied
when there is no active RF connection.