page 113
1,2 - 2,0 t A.C.
SERVICE MANUAL
Electric
036-0410-07
MAIN MENU:
PARAMETER CHANGE (Mhyrio connection number 9)
Press ENTER
Press ENTER
Scroll the parameters using ROLL and save the new values pressing OUT and then ENTER
MIN EVP
Min voltage on the draining solenoid valve
MAX EVP
Max voltage on the draining solenoid valve
MIN EVP1
Min. voltage on the lowering solenoid valve
MAX EVP1
Max voltage on the lowering solenoid valve
MIN EVP2
Min. voltage on the lifting solenoid valve
MAX EVP2
Max voltage on the lifting solenoid valve
MIN EVP3
Min voltage on the backward tilt solenoid valve
MAX EVP3
Max voltage on the backward tilt solenoid valve
MIN EVP4
Min voltage on the forward tilt solenoid valve
MAX EVP4
Max voltage on the forward tilt solenoid valve
MIN EVP5
Min voltage on the sideshift right solenoid valve
MAX EVP5
Max voltage on the sideshift right solenoid valve
MIN EVP6
Min voltage on the sideshift left solenoid valve
MAX EVP6
Max voltage on the sideshift left solenoid valve
MIN EVP7
Min voltage on the 4th way forward solenoid valve
MAX EVP7
Max voltage on the 4th way backward solenoid valve
MIN EVP8
Min voltage on the 5th way forward solenoid valve
MAX EVP8
Max voltage on the 5th way backward solenoid valve
EVP OPEN DELAY
Delay of the EVP in opening
EVP CLOSE DELAY
Delay of the EVP in closing
EVP1 OPEN DELAY
Delay of the EVP1 in opening
EVP1 CLOSE DELAY
Delay of the EVP1 in closing
EVP2 OPEN DELAY
Delay of the EVP2 in opening
EVP2 CLOSE DELAY
Delay of the EVP2 in closing
EVP3 OPEN DELAY
Delay of the EVP3 in opening
EVP3 CLOSE DELAY
Delay of the EVP3 in closing
EVP4 OPEN DELAY
Delay of the EVP4 in opening
EVP4 CLOSE DELAY
Delay of the EVP4 in closing
EVP5 OPEN DELAY
Delay of the EVP5 in opening
EVP5 CLOSE DELAY
Delay of the EVP5 in closing
EVP6 OPEN DELAY
Delay of the EVP6 in opening
EVP6 CLOSE DELAY
Delay of the EVP6 in closing
EVP7 OPEN DELAY
Delay of the EVP7 in opening
EVP7 CLOSE DELAY
Delay of the EVP7 in closing
EVP8 OPEN DELAY
Delay of the EVP8 in opening
EVP8 CLOSE DELAY
Delay of the EVP8 in closing
MAIN MENU
PARAM. CHANGE
MHY CB
ZP 0.11
48V
0A
00000
Summary of Contents for BT BLITZ 312
Page 7: ...chapter A page 3 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07 TECHNICAL DATA...
Page 8: ...chapter A page 4 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 9: ...chapter A page 5 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 11: ...chapter 0000 page 1 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07 CHAPTER 0000 CHASSIS...
Page 175: ...chapter 5000 page 123 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07 WIRING DIAGRAMS...
Page 176: ...chapter 5000 page 124 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 177: ...chapter 5000 page 125 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 178: ...chapter 5000 page 126 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 179: ...chapter 5000 page 127 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 180: ...chapter 5000 page 128 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 181: ...chapter 5000 page 129 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 182: ...chapter 5000 page 130 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 183: ...chapter 5000 page 131 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 184: ...chapter 5000 page 132 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 201: ...chapter 7000 page 1 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07 CHAPTER 7000 MAST GROUP...
Page 217: ...chapter 8000 page 1 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07 CHAPTER 8000 ATTACHEMENT...
Page 219: ...chapter 9000 page 1 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07 CHAPTER 9000 OPTIONS...