chapter 5000
page 47
1,2 - 2,0 t A.C.
SERVICE MANUAL
Electric
036-0410-07
* :
ON= active when the switch is closed (+ BATT)
OFF= not active when the switch is opened (GND)
TESTER
MHYRIO UNIT
BATTERY VOLTAGE:
level of battery voltage measured with the key switch ON.
VALVES SUPPLY:
level of voltage at the positive valve supply (0-VB).
CAN POT EVP:
single proportional valve current setpoint, received by the canbus
(% of the current supplied to the valve).
CAN POT GROUP 1:
group 1 proportional valves current setpoint, received by canbus
(0-100 % of the current supplied to the lifting, proportional % for the
lowering valve).
CAN POT GROUP 2:
group 2 proportional valves current setpoint, received by the canbus
(0-100 % of the current supplied to the tilt box)
CAN POT GROUP 3:
group 3 proportional valves current setpoint, received by the canbus
(0-100 % of the current supplied to the side-shift box)
CAN POT GROUP 4:
group 4 proportional valves current setpoint, received by the canbus
(0-100 % of the current supplied to the 4° Way box)
INPUT 0:
state of DIGITAL INPUT 0:
ON / +VB : active input, closed switch
OFF / COND : non-active input, open switch
INPUT 1:
state of DIGITAL INPUT 1:
ON / +VB : active input, closed switch
OFF / COND : non-active input, open switch
INPUT 2:
state of DIGITAL INPUT 2:
ON / +VB : active input, closed switch
OFF / COND : non-active input, open switch
ANALOG INPUT 1:
voltage of the analog input.
not used
Summary of Contents for BT BLITZ 312
Page 7: ...chapter A page 3 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07 TECHNICAL DATA...
Page 8: ...chapter A page 4 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 9: ...chapter A page 5 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 11: ...chapter 0000 page 1 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07 CHAPTER 0000 CHASSIS...
Page 175: ...chapter 5000 page 123 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07 WIRING DIAGRAMS...
Page 176: ...chapter 5000 page 124 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 177: ...chapter 5000 page 125 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 178: ...chapter 5000 page 126 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 179: ...chapter 5000 page 127 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 180: ...chapter 5000 page 128 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 181: ...chapter 5000 page 129 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 182: ...chapter 5000 page 130 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 183: ...chapter 5000 page 131 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 184: ...chapter 5000 page 132 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07...
Page 201: ...chapter 7000 page 1 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07 CHAPTER 7000 MAST GROUP...
Page 217: ...chapter 8000 page 1 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07 CHAPTER 8000 ATTACHEMENT...
Page 219: ...chapter 9000 page 1 1 2 2 0 t A C SERVICE MANUAL Electric 036 0410 07 CHAPTER 9000 OPTIONS...