© Cesab
8 – 49
T Code(s): 841, 842, 843
Repair manual: Troubleshooting
Model(s): S210, S212, S212S, S212L, S214, S214L, S220D
Publication Number: 7588857-040
Date: 2018-05-01
Applies from serial number: 6384351-
8.8.4 The truck can be driven, but some functions do not work
Software compatibility
Ensure that the correct software for logic card [A5], motor control [T1] and
battery charger [A30] is installed on the truck. See section “8.1 General”.
Hardware compatibility matrix
Make sure the correct software for the logic card [A5] and motor control [T1]
are installed on the truck by referring to the matrix below.
Motor control
ACT[T1]
not
replaced
Motor control
ACT[T1]
replaced
ICH
logic card
[A5] not
replaced
OK
Warning 2.004. Use TruckCom
to download new backup values.
Open TruckCom, and select
“Copy configuration to
secondary unit: ACT”
ICH
logic card
[A5] replaced
Error code 2.101. Use TruckCom
to upload new backup values.
Select “Copy configuration to
primary unit: ICH”
Replace one node at a time and
implement the corresponding
measure. See 17.2 and 16.5.2
https://www.forkliftpdfmanuals.com/