5.2.2 Description
Parameter 101/104 – Service/Log-out
#101 - Service intervals
This parameter determines the time value (in hours) to the next service from
0 to 2000 hours in increments of 50 hours. Whenever this value is changed,
the timer is reset and will start to count the truck activity time. On reaching the
set value, code “S - 0h” is shown on the display and the red LED flashes.
If the value is set as '0', no service interval is given
#104 - Time to automatic log-out
Gives the time, in minutes, before automatic log-out if the truck is inactive.
If the value is set as ‘0’, logout takes place after 4 hours.
Parameter 102 - Operator access
#102 - Operator access
Specifies which login method should be used and if the operator will have the
possibility of changing the operator parameter settings.
Values 1 and 2 = Key
Values 3 and 4 = Keypad with 100 PIN codes. See section “6.6 Programming
PIN codes”.
Values 5 and 6 = Keypad with DHU
Values 7 and 8 = ID unit
Values 9 and 10 = SA2
Odd values = Operator parameters are open and can be changed by the
operator.
Even values = Operator parameters can only be changed with a CAN key
connected.
Par.
Description
Min.
Defa
ult
Max.
Incre
ment
Unit
101
Service intervals
0
0
2000
50
h
104
Time to automatic logout
0
20
20
1
min.
Par.
Description
Min.
Defa
ult
Max.
Incre
ment
Unit
102
Operator access
1
3
10
1
https://www.forkliftpdfmanuals.com/