Steps
Signal
1. Hold the System-Master for approx. 1 second in the reading field of the locking device and
then remove it.
The System-Master has been accepted.
1x
short green
2. Hold the System-Master once again for approx. 1 second in the reading field of the locking
device and then remove it.
The System-Master is now authorised for this locking device.
1x
long green
Troubleshooting:
Signal
Cause
Solution
After step 1:
4x
short red
The System-Master
does not have the
correct system
number.
Use the System-Master with the correct system number.
After step 2:
1x
short red
Another System-
Master has already
been authorised for
this locking device.
Since, at any given time only one System-Master exists
that can be authorised on the basis of its unique system
number for a locking device, there is reason to suspect
manipulation. Contact your CEStronics partner
immediately.
RFID furniture lock
Page
59
of
84
13.1 Authorising the System-Master
Overview:
Use
of
master
media
Help
&
troubleshooting
T
echnical
dat
a
Maintenance
&
disposal
Operation
Administration
Assembly
Basic
information