Fitting the locking cylinder in a door lock
RF-Master-Set
25
Removing the reader
NOTICE
The locking cylinder contains sensitive
electronic components that may be damaged
or destroyed through static charges.
Do not disassemble the RF-Master-Set in rooms
with a high built-up static charge.
The reader module is fitted in the outside knob and fastened to
the outside knob with two screws.
Proceed as follows to remove the reader module:
NOTICE
The Flexprint connection cable attached to the
reader module may be damaged when the
reader module is pulled out.
Always pull the reader module slowly and
carefully out of the outside knob.
Avoid mechanical strain on the Flexprint cable.
Make sure not to squeeze the Flexprint cable.
Check the correct fit.