Care 

64 

RF-Master-Set 

Care 

The outer accessible parts of your locking devices such as 
knobs, knob sleeves, covers, fittings, etc. can be cleaned with 
a soft, slightly moist wipe. 

 

NOTICE

 

Risk of damage to surfaces of the OMEGA 
cylinder! 

 

Never use solvent-containing cleaning agents to 
avoid damage to your locking devices. 

Maintenance 

 

Have the RF-Master-Set serviced and its perfect functioning 
verified every six months by CEStronics or by a CEStronics 
partner only. 

 

Replace the batteries in line with a defined maintenance 
schedule. 

 

Make sure to have replacement batteries ready in good 
time. 

Spare Parts 

The RF Master Set does not require any spare parts for you to 
change. 

 

If you need service, please contact your professional CES 
partner. 

Summary of Contents for RF-Master-Set

Page 1: ...RF Master Set Fitting and Operating Instructions Translated fitting and operating instructions version 1 54t 04 2013...

Page 2: ...Fitting and Operating Instructions These Fitting and Operating Instructions should be kept near the RF Master Set at all times Notes on the layout In these Fitting and Operating Instructions various e...

Page 3: ...12 Manufacturer 12 Service 12 Introduction 13 Description 13 Optional Master media 15 System components 18 Scope of delivery 19 Fitting the locking cylinder in a door lock 22 Unpacking the locking cy...

Page 4: ...46 Using the RF Switchpoint 53 Commissioning 53 Using the remote authorization 57 Lost master or locking medium 59 Emergency opening 60 Care 64 Maintenance 64 Spare Parts 64 Trouble shooting 65 Dispo...

Page 5: ...y instructions must be observed Danger to life Do not use the RF Master Set for doors with anti panic function such as escape doors for which a knob cylinder is not permitted Otherwise people may not...

Page 6: ...ordless screwdrivers when fastening the RF Master Set Only use the proper tools to open the locking cylinder When fitting the locking cylinder make sure that the lock and the plate rose are in a perfe...

Page 7: ...se the RF Master Set in corrosive atmospheres chlorine ammonia lime water Only use the RF Master Set in rooms in which the humidity does not exceed 95 Do not use the RF Master Set in rooms with a high...

Page 8: ...orrect polarity when inserting the batteries Never attempt to recharge non rechargeable batteries There is a risk of explosion Never short circuit the batteries Always store batteries at a cool dry pl...

Page 9: ...ude safety notes of the following types DANGER DANGER notes warn against hazards that may directly result in severe or fatal injuries CAUTION CAUTION notes warn against hazards that may result in slig...

Page 10: ...ermitted It is exclusively intended and may only be used for that purpose The knob of the locking cylinder must not be used for opening the door Any other use is considered to be improper and may resu...

Page 11: ...For your safety RF Master Set 11 CE Declaration of Conformity...

Page 12: ...s are only valid for CEStronics RF Master Set Manufacturer The manufacturer from the RF Master Set is CEStronics GmbH Friedrichstr 243 42551 Velbert Tel 49 0 2051 204 0 Fax 49 0 2051 204 105 www ces e...

Page 13: ...ween the RF Switchpoint and the locking cylinder may be up to 10 m allowing a wide range of use of the devices inside the building The RF Switchpoint was designed to allow incorporation in both CES st...

Page 14: ...r One freely rotating knob with reader Mifare Classic transponder technology Integrated 868 MHz RF transceiver Integrated evaluation unit with memory for Up to 100 transponder keys Up to five Master m...

Page 15: ...system there is one and only one valid SYSTEM MASTER With the SYSTEM MASTER you can authorize up to ten PROGRAM MASTERS In its basic version a locking system requires one SYSTEM MASTER and one PROGRAM...

Page 16: ...et this is the period during which the knob is coupled with the follower time When the locking cylinder or access terminal detects the TIME MASTER it starts beeping at one second intervals The number...

Page 17: ...en LED of your locking cylinder IES fitting or wall terminal flashes twice the RF link is very good If the green LED of your locking cylinder IES fitting or wall terminal flashes once the RF link is a...

Page 18: ...e the locking cylinder with the following locking media transponder key key fob key fob slimLine card 2 RF Switchpoint 3 Locking cylinder 4 SYSTEM MASTER The SYSTEM MASTER is used to authorize the PRO...

Page 19: ...ing system In this case you can use transponder keys for both mechanical and electronic locking cylinders from CEStronics Scope of delivery Before fitting and commissioning please check the contents o...

Page 20: ...for the outside knob 6 Flexprint cable for the connection between the inside and the outside electronics 7 Cylinder body 8 Follower 9 Electronics module with battery compartment 10 Inside knob 11 Bat...

Page 21: ...bit for fixing screw 3 Combination tool three square hexagon socket key 4 14 m flat wrench 5 Belt grip The combination tool the flat key and the TORX bit are supplied with the RF Master Set The tools...

Page 22: ...onics or a CEStronics partner Before fitting verify that the cylinder body has the correct length for the door lock by measuring the thickness of the door leaf and the length of the cylinder body The...

Page 23: ...b systems are allowed Contact the manufacturer of the door or the door lock in case of doubt DANGER In case of malfunctions it may not be possible to open the door in emergency situations which could...

Page 24: ...t the door is not exposed to driving rain Do not leave the door open when it is raining IP 54 Protection against touching with tools wires etc protection against internal dust accumulation protection...

Page 25: ...up static charge The reader module is fitted in the outside knob and fastened to the outside knob with two screws Proceed as follows to remove the reader module NOTICE The Flexprint connection cable a...

Page 26: ...he combination tool three square screwdriver These screws cannot be completely screwed out but will always be held in the outside knob NOTICE The connection cable attached to the reader module may com...

Page 27: ...ter Set 27 Pull the reader module out of the outside knob until you feel the stop Now push the reader module back into the outside knob by about 5 mm 1 and rotate the reader module in the direction of...

Page 28: ...tion cable is plugged in at the reader module The plug is locked by a clamping bridge To release the connection proceed as follows Carefully pull the clamping bridge in the direction of the arrow 1 to...

Page 29: ...are arranged in the interior of the outside knob To release the outside knob from the cylinder body proceed as follows Release the two screws in the interior of the outside knob with the combination t...

Page 30: ...ing Ensure that a locking medium authorized for this cylinder is available Make sure that the authorizations for the locking cylinder concerned are granted correctly Please refer to the enclosed Progr...

Page 31: ...llation of the cylinder body If not proceed as follows Pull the fitting aid out of the profile cylinder hole Correct the position of the door lock If required contact the manufacturer of the lock Agai...

Page 32: ...body into the profile cylinder hole of the door lock Rotate the inside knob to verify that the follower can move free of friction If the movement of the follower is impeded by friction remove the cyl...

Page 33: ...ess screwdriver or drilling machine for fitting the RF Master Set Only use the tool specified for this purpose Insert the fixing screw into the door lock and initially screw it in only until it is flu...

Page 34: ...ening the outside knob to the cylinder body Once the cylinder body has been fitted in the door lock the outside knob must again be attached to the cylinder body Proceed as follows Thread the connectio...

Page 35: ...g cylinder in a door lock RF Master Set 35 Push the outside knob onto the shaft at the cylinder body Hand tighten the two screws in the interior of the outside knob with the combination tool hexagon s...

Page 36: ...After the outside knob has been fastened to the cylinder body you can again insert the reader module into the outside knob Proceed as follows Push the plug of the Flexprint connection cable into the s...

Page 37: ...on of the arrow onto the clamp joint to lock the clamp joint NOTICE The connection cable may be damaged when the reader module is inserted into the outside knob Always push the reader module into the...

Page 38: ...the connection cable carefully into the outside knob and insert the reader module into the outside knob Push the reader module into the outside knob until you feel the stop 1 Rotate the reader module...

Page 39: ...two opposite screws using the combination tool three square screwdriver Rotate the inside knob so as to verify the easy movement of the follower If the follower moves easily hand tighten the fixing s...

Page 40: ...lock Correct door operation NOTICE Damaging the double knob cylinder by false door operation possible Use only the door handle for opening and closing the door like shown in the illustration Don t op...

Page 41: ...e with your authorized locking system 1 into the reading range of the locking cylinder This range is about 20 mm The reader module in the outside knob identifies the locking medium The locking cylinde...

Page 42: ...is not authorized to enable this locking cylinder the light ring of the locking cylinder flashes red four times and you hear four successive beeps In this case the outside knob is not coupled with th...

Page 43: ...the locking device and the locking medium is encrypted Only locking media that are authenticated by the device are authorized to lock or unlock This ensures a very high protection against manipulatio...

Page 44: ...king cylinder sends a short signal to signal the enable status During the opening time you can open the door During this opening time the locking cylinder does not respond to any other locking media T...

Page 45: ...lowing notes Always keep locking cylinders at least 5 cm apart If this is not possible remove the battery of the locking cylinder please refer to page 46 Do not transport locking cylinders together wi...

Page 46: ...ted in the electronics module in the inside knob To replace the battery the locking cylinder must be pulled out slightly so that you can apply the flat key to release the cover Proceed as follows NOTI...

Page 47: ...d Only use batteries of the CR2 type with 3 V To replace the battery the locking cylinder must be pulled out slightly so that you can apply the flat key to release the cover Proceed as follows Apply t...

Page 48: ...pull off the cover in the direction of the arrow NOTICE The battery the housing of the electronics module and or the electronics may be damaged if you try to pry out the battery with an object Only us...

Page 49: ...cylinder RF Master Set 49 Put your finger lightly on the contact plate 1 to prevent the battery from being pushed out Carefully release the catch 2 in the direction of the arrow until the contact pla...

Page 50: ...Replacing the battery of the locking cylinder 50 RF Master Set Take the battery out of the battery compartment Insert the new battery with the correct polarity into the battery compartment...

Page 51: ...CAUTION Incorrectly inserted batteries may cause irreparable damage to your locking cylinder Always insert the batteries with the correct polarity into your locking cylinder If a battery has been inse...

Page 52: ...onto the electronics module Satisfy yourself that the sealing gasket sits perfectly on the thread of the electronic module Manually screw on the cover clockwise rotation Tighten the cover with the fla...

Page 53: ...nals The remote authorization is triggered by a contact or a higher order control system connected to the enable input 3 at the RF Switchpoint 1 If the contact 3 is closed for one second the locking c...

Page 54: ...rs into a group for connection with the RF Switchpoint You will also need the RF INI Master medium to set the locking cylinder into its learning mode Condition The RF INI Master must have been enabled...

Page 55: ...short circuiting or touching any other points or contacts on the board when bridging the reset bridge RB 1 NOTICE Incorrect bridging may damage the RF Switchpoint Be sure to avoid short circuiting or...

Page 56: ...The cylinder is now in its learning mode A maximum of four cylinders can be enabled To end the learning mode activate the reset bridge This is acknowledged by four short consecutive flashes of the gre...

Page 57: ...input 1 When the enable input is actuated the RF Switchpoint is switched over into Authorization mode which is signalled by the green LED in the RF Switchpoint When the contacts are closed the Author...

Page 58: ...u want to trigger the authorizations push button higher order control etc with the enable input Trigger the authorization Rotate the outside knob of the locking cylinder by a couple of notches Release...

Page 59: ...accessible to unauthorized persons NOTICE When a Master medium is lost the potential finder may manipulate the locking system If a Master medium has been lost have the locking cylinder and or the acce...

Page 60: ...require the authorized locking medium to confirm that you have authorized access The Emergency Power Supply is not part of the scope of delivery of the locking cylinder To order it please contact your...

Page 61: ...ing RF Master Set 61 Release the two opposite screws on the outside knob with the combination tool three square screwdriver These screws cannot be completely screwed out but will always be held in the...

Page 62: ...rgency Power Supply with the interface 2 on the reader module Observe the notes and instructions in the Operating Instructions of the Emergency Power Supply Use your authorized locking medium to open...

Page 63: ...e of the outside knob To fasten the reader module hand tighten the two opposite screws with the combination tool three square screwdriver Replace the battery of the locking cylinder after each emergen...

Page 64: ...g agents to avoid damage to your locking devices Maintenance Have the RF Master Set serviced and its perfect functioning verified every six months by CEStronics or by a CEStronics partner only Replace...

Page 65: ...um is not authorized for this cylinder Use an authorized locking medium The battery is empty Replace the battery of the locking cylinder with a new one see page 46 The locking medium is not within the...

Page 66: ...rded with the normal household waste Ask your local authorities about recycling and or the proper disposal of the device in line with environmental regulations Used batteries should be delivered at a...

Page 67: ...Technical data RF Master Set 67 Technical data Locking cylinder 1 Outside knob locking side 2 Inside knob knob side...

Page 68: ...r media max 1 SYSTEM MASTER max 5 PROGRAM MASTERS Permissible temperature at outside knob 25 C to 70 C Permissible temperature at inside knob 0 C to 50 C Prohibited atmospheres Not suitable for use in...

Page 69: ...er Set 69 RF Switchpoint 1 Not used yet for future model specific options 2 Interface for emergency power supply 3 Connection for enabling input 1 NOC normally open contact 4 Connection for power supp...

Page 70: ...e to cylinder approx 10 Meters Data transfer Encrypted 128 Bit AES Power supply 8 28 V AC DC 100 mA Enabling input 1 NOC normally open contact Permissible temperature 0 C up to 50 C Prohibited atmosph...

Page 71: ...linder Master media Media for programming the RF Master Set Profile cylinder hole Recess in the door lock for accommodating a profile cylinder PROGRAM MASTER Master medium that is authorized to progra...

Page 72: ...Start of programming Beeper LED green 1 short On as long as medium is within range End of programming Beeper LED green 1 long On as long as medium is within range Acknowledgement of programming Beeper...

Page 73: ...ing Signal type Signal Enabling RF mode Beeper LED green 1 short after leaving reading range On as long as medium is within range Disabling RF mode Beeper LED green 1 long after leaving reading range...

Page 74: ...Beeper LED green 1 long after laving reading range On as long as medium is within range Learning mode enabled LED green 1 short Acknowledgement of learning mode LED green 1 long Trouble and error mes...

Page 75: ...influence damage as a consequence of improper operation damage as a consequence of omitted maintenance work damage as a consequence of excess voltage damage as a consequence of fire water or smoke Al...

Page 76: ...1 204 229 info ces locks de CESitalia srl V d vecchie Fondamenta 4 Stra e d A Gr ndungen 4 I 39044 Egna Neumarkt BZ 39 0471 812 294 39 0471 812 294 info it ces eu www ces eu it CESrom srl Str Metalurg...

Reviews: