For your safety
OMEGA Mifare wall terminals
7
The wall terminals contain highly sensitive electronic parts
that may be damaged or destroyed through static charges.
Do not disassemble the wall terminals in rooms with built up
static charge. Ensure potential equalization when working
on the wall terminals to remove any static charge.
Do not use the wall terminals in corrosive atmospheres
(chlorine, ammonia, lime water).
Only use the wall terminals in rooms in which the humidity
does not exceed 95 %.
Do not use the wall terminals in rooms with a high level of
dust formation.
Do not use the wall terminals near sources of heat.
Do not expose the wall terminals to temperatures below
-25 °C or above +70 °C.
Danger of malfunctions
Do not cover the reader in the wall terminals with metallic
material.
If you fit wall terminals on metallic surfaces, always use the
supplied fitting frame.
Check the proper functioning before fitting the wall
terminals.
The wall terminals may not be fitted directly on
metal surfaces because the sending and receiving
frequencies of the reader will be detuned by the
magnetic properties of the metals. Depending on
the metal material, the reading range of the wall
terminal may be reduced to ZERO.