background image

Villar, 20 - 08041 Barcelona (Spain) - Tel. (34) 934.335.240 - Fax. (34) 933.479.310 - e-mail: info@cesva.com - www.cesva.com 

SC160 

Dosimeter module for the assessment of 
noise in the workplace 

The dosimeter module of the 

SC160

 for the assessment of noise in 

the workplace adds a new measurement mode that is ideal for the 
application of Directive 2003/10/CE, which adapts the regulation on 
protection of the health and safety of workers from the risks of expo-
sure to noise, to technical progress. In the member states, the cor-
responding transposition to national law applies. 

This  dosimeter  module  allows  you  to  simultaneously  measure  all 
parameters  needed  to  assess the  levels  of  noise  to  which  workers 
are exposed when wearing hearing protectors, or not, (SNR, HML, 
Octaves). 

The 

SC160

  measures,  simultaneously,  the  equivalent  level  with  A 

and  C  frequency  weighting  [  L

At

,  L

Ct 

],  daily  noise  exposure  level 

[  L

EX,8h 

]  (ISO  1999),  noise  exposure  in  Pa

2

h  [  E  ]  and  noise  dose 

[  DOSE  ]  with  reference  to  a  programmable  criterion  level  [  L

], 

and,  of  course,  also  the  Peak  Level  with  C  frequency  weighting   
[L

Cpeak

] (ISO 1999). 

Moreover, the 

SC160

 allows you to carry out the measurement dur-

ing a time shorter than the exposure time, because it shows on the 
screen  all  parameters  projected  to  the  expected  exposure  time 
(programmable projection time [ t

] ). 

To evaluate the exposure to noise, taking into account the attenua-
tion  of  the  individual  hearing  protectors  worn  by  the  worker,  the 

SC160

,  besides  measuring  the  equivalent  level  with  A  and  C    fre-

quency  weightings  [  L

At

,  L

Ct 

]  (SNR  and  HML  method),  simultane-

ously  carries  out  a  real  time  frequency  analysis  with  A  frequency 
weighting  and  by  octave  bands  from  63  Hz  to  8  kHz  (Octave 
method). 

The large memory of the 

SC160

 allows you to store the time history 

of  the  parameters  measured,  and  afterwards  recalculate  them  for 
any desired time interval. 

The 

SC160 

helps you to asses and measure the exposure to noise 

and also brings you all the data needed to inform and train workers 
with  regard  to  the  significance  and  potential  risks  of  the  results  of 
the assessment and measurement. 

Moreover,  It  helps  you  to  design  and  run  a  reduction  programme 
and to choose the most suitable hearing protectors. 

The dosimeter module for the assessment of noise in the workplace 
is  not  included  with the 

SC160

. It  is  an  optional module  and  it  can 

be acquired when buying the 

SC160

 or later. 

Dosimeter module for the assess-
ment of noise at workplace 

 

Numeric screen  

 

Graphic screen 

 

1/1 Spectrum analyser* screen 

 

Numeric screen (projected parameters) 

 

Summary of Contents for SC160

Page 1: ... Z with frequency weight ings Within the analyser mode there is a special screen to evaluate room noi se especially designed for HVAC system installers engineers and consultants that allows you to asses noise in real time using the NC and NR curves criterion Applications Evaluation of the noise exposure of workers at workplace simultaneously to the verification of PPE Personal Protective Equipment...

Page 2: ... Peak sound pressure level t Measurement time T Integration time Ln n 1 5 10 50 90 95 99 Percentiles with A frequency weighting 31 5 63 125 250 500 1k 2k 4k 8k 16k Nom Description of analyser mode 1 1 functions LXT Equivalent continuous sound pressure level with T integration time LXT_f Equivalent continuous sound pressure level with T integration time for the f octave band selected See graphic be...

Page 3: ...onverter cable CN DAT AC output audio cable TR 40 Tripod height 1 1 m TR050 Tripod height 1 55 m TR002 Tripod support for cable CNR ITV A 200 Mains feeder 230 V 50 Hz to 9 V A 100 Battery converter 12 V to 9 V ML 50 Transport briefcase 49 x 36 x 14 cm ML 10 Transport briefcase 39 x 32 x 12 cm ML060 Special outdoors transport briefcase 51x38x15 cm IM003 Printer 40 columns serial RT 030 Reverberatio...

Page 4: ...ency weighting Each T T 1 s 4 hours 45 minutes T 1 min 11 days 21 hours T 5 min 2 months T 1 hour 2 years The SC160 can store in its internal memory the values of the func tions measured When the unit is switched off the data is saved and may be retrieved and displayed directly from the SC160 or transferred to a PC The memory may be erased directly from the SC160 In the memory of the SC160 may be ...

Page 5: ... range LF LS LI LT and Lt Indicator limits 0 137 dB Primary range A C Z Upper limit 113 113 113 Lower limit 36 36 40 Measurement range Upper limit 137 137 137 Crest factor 3 130 130 130 Crest factor 5 126 126 126 Crest factor10 120 120 120 Lower limit 19 21 32 Lpeak Indicator limits 0 140 dB Peak detector Lpeak Onset time constant 75 µs Noise Electrical noise A C Z Maximum 12 12 1 23 1 Typical 9 1...

Page 6: ... Influence of humidity Operation range 25 to 90 Maximum error at 25 R H 90 at 40 ºC and 1 kHz 0 5 dB Storage without batteries 93 Effects of magnetic fields In an 80 A m magnetic field 1 oersted at 50 Hz a reading of less than 25dB A is given Influence of temperature Operation range 10 to 50 ºC Maximum error 10 to 50ºC 0 5 dB Storage without batteries 20 to 60 ºC Effects of vibrations For frequenc...

Page 7: ... SC160 memory to a PC Erase the SC160 memory Display graphically and numerically the data files and convert them into different formats txt xls mdb System of encrypted file The files are saved in their own ccf format and cannot be changed which guarantees their total integrity and legality Data exportation to other applications CAPTURE Studio provides you with a convenient use friendly environment...

Page 8: ...T30 and decay curves for all octave bands The reverberation time module for the SC160 is optional and may be purchased when buying the SC160 or later All SC160 pur chased before this date may be upgraded with this module Below a graphic is shown with the steps that must be followed to make a reverberation time measurement Storage Capacity Reverberation time T20 and T30 Background noise LN maximum ...

Page 9: ...an the exposure time because it shows on the screen all parameters projected to the expected exposure time programmable projection time tp To evaluate the exposure to noise taking into account the attenua tion of the individual hearing protectors worn by the worker the SC160 besides measuring the equivalent level with A and C fre quency weightings LAt LCt SNR and HML method simultane ously carries...