CET - s.r.l.
Vers. 1.1
LCM 60
Pag. 2
FRONTAL KEYBOARD DESCRIPTION
ø
YELLOW
The key 'LEFT ARROW' in normal operating phase visualizes, blinking, all the programmings executed
without the limitation of the insertion code. The time of scansion of the programmings is given from the
pressure of the same key. It exits automatically from this phase after 5 sec of the last pressure of the
same key.
In programming phase it moves the cursor of the figure towards left of a step, than at the beginning it is
on the right side first one on the. At the end it resumes from the first one to right.
ù
YELLOW
The key 'UP ARROW' in normal operating phase visualizes the totalizer of impulses.
In programming phase it increases the value of the blinking figure.
ú
BLUE
The key 'PRG' pressed for 2 sec. allows to enter in the programming phase, visualizing on display
C.0000.
In the programming phase, pressing key 'PRG' impulsively, it exits from the programming phase. The
instrument exits automatically from the programming phase, 60 sec. after the pressure of the last key.
û
RED
The key 'ENT/RES' in normal phase of counting has the 'RESET' function, with the modalities to it
attributed in the programming phase.
In programming phase it confirms and memorizes the visualized data and passes to the successive
function. If it has arrived to list end it resumes from the beginning.
INPUT / OUTPUT DESCRIPTION
DC POWER
(inputs 1-2)
24V DC Power Supply of the instrument.
AC POWER
(inputs 1-2)
AC Power Supply of the instrument; it can be to 24 - 110 - 230 VAC according to demand.
24 VDC - 100mA
(inputs 5 - 6)
24 VDC - 80 mA auxiliary Power Supply that the instrument supply to feed the Encoder and amplified
proximity.
INPUT
(input 7)
Input of count adapted for electromechanical and logical contacts, encoder and 3 wires proximity
amplified, configurable in Positive (PNP) and Negative (NPN) logic by the dip switches on the rear.
RESET
(input 8)
Input of RESET that executes the reset visualized count showed on display at the moment of its
activation.
INHIBIT
(input 9)
Input of count inhibition: when activated it blocks the count of the normal counter and the totalizer.