background image

CET   -   s.r.l. 

  Vers. 1.1   

LCM 60 

 

Pag. 3 

 

 
 

PROGRAMMING OF THE OPERATION PARAMETERS 

The programmable parameters are divided in two groups and protect with a 4 figures code. 

In order to approach the programming, proceed in the following way: 

   - Press key PRG for about 2 sec. On the display appears: 

Cod 

 

0000 

 

GROUP 1

 : 

in order to approach the parameters of group 1, insert code 

2357

 

 and  press 

 

ENT    

 

 

Æ1 “ 

©0000 

 

 

6  digits  multiplier,  programmable  from  0,1  to  9.99999.This  parameter  allows  to  convert  the 
number of the input impulses, showing them on the display in an other format. If it programmed 
= 0 it comes reprogrammed automatically to 1. If a value lower than 1 is inserted, it obtains the 
division of the impulses. Es. I want to divide for 25 the impulses in input; calculation 1 : 25 = 
0.04.  
Attention: the variation of the value of the multiplying modifies automatically the value of the 
count and the totalizer. 

 

 

Æ2 10 

 

 

 

2 digits multiplier, programmable from 1 to 99.This parameter allows to convert the number 
of the input impulses, showing them on the display in an other format. If it programmed = 0 it 
comes reprogrammed automatically to 1. 

Attention: the variation of the value of the multiplying modifies automatically the value of the 
count and the totalizer. 

 

 

1æ  F 
1æ  5 

 

 

Input Fast - Slow. 
This  programming  allows  to  predispose  the  input  of  count  to  read  signals  coming  from 
electromechanical contacts  (relay,  switches  etc.)  that  introduces  false  signals,  or  from  logical 
signals like proximity, encoder, transistor etc.) 
In = F. predisposes the instrument in order to read to logical signals up to 15 KHz. 
In = S. predisposes the instrument in order to read to electromechanical contacts up to 25 Hz. 

 

 

Summary of Contents for LCM60

Page 1: ...TECHNICAL FEATURES POWER SUPPLY IN ALTERNATE CURRENT POWER SUPPLY IN DIRECT CURRENT POWER SUPPLY TOLERANCE ABSORPTION OPERATING TEMPERATURE CLIMATIC CONDITIONS COUNTER AND TOTALIZER VISUALIZATION MULTIPLICATION FACTOR M1 OF THE INPULSES IN INPUT MULTIPLICATION FACTOR M2 OF THE INPULSES IN INPUT INPUT TYPE COUNT FREQUENCY FOR LOGICAL SIGNALS MINIMUM TIME FOR COUNT IMPULSES CUT FREQUENCY FOR ELECTRO...

Page 2: ...its automatically from the programming phase 60 sec after the pressure of the last key ûRED The key ENT RES in normal phase of counting has the RESET function with the modalities to it attributed in the programming phase In programming phase it confirms and memorizes the visualized data and passes to the successive function If it has arrived to list end it resumes from the beginning INPUT OUTPUT D...

Page 3: ...lses in input calculation 1 25 0 04 Attention the variation of the value of the multiplying modifies automatically the value of the count and the totalizer Æ2 10 2 digits multiplier programmable from 1 to 99 This parameter allows to convert the number of the input impulses showing them on the display in an other format If it programmed 0 it comes reprogrammed automatically to 1 Attention the varia...

Page 4: ...È 5 Programming of the Decimal Point of the Counter and the Totalizer This programming allows to add a decimal point to the visualization on the 5 digits in order to obtain counts with various resolutions d p 0 Decimal Point excluded visualization 999999 d p 1 Decimal Point on the second display from right visualization 99999 9 d p 2 Decimal Point on the third party display from right visualizatio...

Page 5: ...CET s r l Vers 1 1 LCM 60 Pag 5 OPERATION DIAGRAMS WORKING WITH MANUAL INHIBIT AND RESET POWER SUPPLY INHIBIT INPUT COUNTING RESET ...

Page 6: ...CET s r l Vers 1 1 LCM 60 Pag 6 Programming Notes ...

Page 7: ...ice Strada Statale 211 Km 53 3 28071 Borgolavezzaro No ITALIA Tel 0039 0 321 885301 Fax 0039 0 321 885560 declare that the products type Electronic Counter model LCM 60 use class Industrial are in conformity with the following normatives EN55011 ENV50141 ENV50204 EN61000 4 2 EN61000 4 4 The constructor CET s r l ________________________________ Signature ...

Page 8: ... CET CETs r l Strada Statale 211 Km 53 550 28071 Borgolavezzaro NO ITALY Tel 39 0321 885180 885301 885807 Fax 39 0321 885560 info cet italy com www cet italy com Agent 48 96 ENT RES PROG L1 L2 863259 Electronic counter LCM CET 139 115 9 15 44x92 REMOVABLE TERMINALS RETAINING BRACKETS 10 MAX 93 45 92 44 1 2 3 4 5 6 7 8 9 10 11 12 13 PROX ENCOD 5 7 6 7 6 7 5 6 7 5 7 6 8 6 9 5 8 5 9 PROX ENCOD 5 7 6 ...

Reviews: