Chapter II About the 4456 Series Digital Phosphor Oscilloscope
8
Fig. 2.11 Feature Setup Area
The Feature Setup Area is composed of the Waveform, Function and Tools Areas. The Waveform Area is
composed of Measure, Display, Analyze, Cursors, Zoom and Navigate keys. The Function Area is composed of
Math, Bus, Meter, Ref, Digital and WaveGen keys. The Tools Area is composed of Print, Save, Utility, Intensity,
Recall and Help keys.
1)
【
Measure
】
: It is used for the setting of the oscilloscope measurement system, including the addition of
measurement parameters, deletion of measurement parameters, histogram measurement and statistical
functions.
2)
【
Display
】
: It is used for the setting of the oscilloscope display system.
3)
【
Analyze
】
: It is used for the advanced analysis function setting of the oscilloscope, including limit/mask
test option and power measurement and analysis option.
4)
【
Cursors
】
: It is used for the cursor measurement function of the oscilloscope, which can realize the cursor
measurement of voltage and time of 4 channels and operation waveform as well as the amplitude and
frequency of the FFT waveform.
5)
【
Zoom
】
: It is used for the multi-window display and double time base measurement function of the
oscilloscope, which observes details of the waveform mainly through different windows.
6)
【
Navigate
】
: It is used for trigger search and waveform recording and playback of the oscilloscope.
7)
【
Math
】
: It is used for the mathematic operation function of the oscilloscope, including basic arithmetic
operation, FFT analysis and advanced mathematics operation.
8)
【
Bus
】
: It is used for protocol trigger and analysis function setting, including analysis functions of 9 serial
buses including I2C, CAN, LIN, RS232, FlexRay, USB, SPI, AUDIO and 1553B.
9)
【
Meter
】
: It is used for function setting of the digital voltmeter, including 4-bit digital voltmeter and 6-bit
hardware frequency meter.
10)
【
Ref
】
: It is used for function setting of the oscilloscope reference waveform.
11)
【
Digital
】
: It is used for function setting of logic analyzer options of 16 channels.
12)
【
WaveGen
】
: It is used for function setting of waveform generator option of 1 channel.
13)
【
】
: It is used for image printing on screen.
14)
【
Intensity
】
: It is used for adjusting screen intensity, division intensity and waveform intensity.
15)
【
Save
】
: It is used for function setting of the oscilloscope waveform saving.
16)
【
Recall
】
: It is used for function setting of the storage setting and recall and waveform playback of the
oscilloscope.
17)
【
Utility
】
: It is used for system menu setting of the oscilloscope, including calibration, configuration and
network setting.
Summary of Contents for 4456 Series
Page 10: ...VIII...
Page 55: ...Chapter V Trigger System 45 Fig 5 51 RF Test Signal Example...
Page 69: ...Chapter VII Mathematical Operation 59 Fig 7 10 Advanced Math Example...
Page 71: ...Chapter VIII Display System 61 Fig 8 3 Wfm Palette Menu Fig 8 4 Normal Palette...
Page 72: ...Chapter VIII Display System 62 Fig 8 5 Inverted Palette Fig 8 6 Temperature Palette...
Page 75: ...Chapter VIII Display System 65 Fig 8 12 XY Display Example...
Page 165: ...Chapter XI Protocol Analyzer Option 155 Fig 11 242 1553 Trigger and Analysis Example...