05-141
5.5 Engine lubrication system
Measurement A
Measurement B
If clearance between outer rotor and its
bore in crankcase exceeds the tolerance,
replace outer rotor assembly and/or
crankcase.
Use a depth gauge to measure the axial
clearance of the oil pump as shown.
Difference between measurements should
not exceed 0.1mm(0.008in). If so, replace
the inner and outer rotor.
Use a depth gauge to measure the axial
depth of the part that extends to oil pump
bore as shown.
Use a depth gauge to measure the axial
depth of the part that extends to oil pump
bore as shown.
Reault: A-B≤0.2mm
Note: When the axial clearance of the
oil pump shaft assembly increases, the oil
pressure decreases.
Installation
Reverse the removal procedure for
installation.
Note: No marks on inner and outer rotor.
When installating outer rotor, no secified
direction for outer rotor. After installation,
check for smooth operation of the oil pump
assembly.
Final Test
After engine is completely reassembled,
start engine and make sure oil pressure
is within specifications(refer to
Engine Oil
Pressure above.)
0514101
0514102
0514103
1 Outer Rotor