05-177
5.8 Cooling System
Oil
Connect the battery and test the relay
again.
1 Thermoswitch 2 Thermometer
3 O-ring
0517702
0517701
Test the relay again with battery connected
as shown in picture 0517701.
Pin
Resistance
30
87
0.5Ωmax.
(Continuous)
If one test failed, replace the relay.
Thermoswitch testing
Drain the coolant.
Remove the thermoswitch.
Follow the right picture to see the thermo
switch ON & OFF temperature. Put the
thermo switch into a pan with water and
a thermometer. Heat the water slowly
to above 88°C and then let it cool. Pay
attention to the temperature when the
thermoswitch turns on and off.
Thermoswitch working temp:
OFF-ON: Approximately 88°C
ON-OFF: Approximately 82°C
WARNING
Do not drop or tap on the thermoswitch
with tools. The thermoswitch will be
damaged. For accurate temperature
readings, do not let thermoswitch or
thermometer touch the pan.
Install the thermoswitch with new O-ring
and tighten the thermoswitch to specific
torque.
Thermoswitch tighten torque:17N·m
Inspect the coolant level after installing a
new thermoswitch. Refill as necessary.
Fan Motor
Battery
Ammeter
1
3
2