CFMOTO
05-190
5.9.1.4 Voltage Regulator
●Measure the resistance between
terminals by a multimeter. If any reading
is out of specification, replace with a new
regulator.
Turn Multimeter to DIODE
●After engine running and battery full
charged,if the voltage between positive
and negative terminal is greater than 15V
or is lower than 12V, replace with a new
regulator.
0519001
Note: When probes of multimeter don’t connect, replace battery if the voltage is
lower than 1.4V.
-
+
1
2
3
(+)
(-)
1
2
3
(-)
(+)
1
∞
∞
100~800
∞
2
∞
∞
100~800
∞
3
∞
∞
100~800
∞
(-)
∞
∞
∞
∞
(+)
100~800
100~800
100~800
100~800