background image

7

6

The C

CX

X3

30

00

00

0G

GS

S  D

Du

uc

ctte

ed

d  A

Aiirr  P

Pu

urriiffiie

err is designed to operate with any heating or air-

conditioning system, up to five tons in size. It is rated for use at standard ambient
air temperatures during heating and air-conditioning functions. It is not rated for
operation at elevated air temperatures in excess of 125 F.

The C

CX

X3

30

00

00

0G

GS

S  uses a four-stage process to purify indoor air:

1.

Electrostatic MERV-11 Filter - removes 0.3 micron allergens and dust

2.

Reactive Catalyst - destroys VOC’s, toxic chemicals and odors

3.

UVC Germicidal Light - kills germs, viruses and bacteria on contact

4.

Negative Ions and Activated Oxygen - keep air fresh and clean

Air purification and sterilization occur whenever the HVAC system fan is operating.
The ultraviolet UVC lamps are always on. They continuously clean and reactivate the
catalyst by burning off surface impurities during periods of non-use, or no airflow.

Do not attempt to clean the photo-catalytic honeycomb core with cleaning solutions.

It is recommended that the C

CX

X3

30

00

00

0G

GS

S operate at least 30 minutes per hour, 24 hours

per day, to remove toxic materials from an indoor environment. For individuals who
may be sensitive to mold spores, dust mites or chemicals, or have respiratory
problems such as asthma, emphysema and chronic allergies, the operating time
should be extended to 40 minutes or more per hour. The actual time of operation
depends on many factors, including the level of ambient pollution or pollen levels,
and individual sensitivity to allergens.

It is recommended that a programmable thermostat be used. These can be set to
provide continuous air circulation, and thus air purification, even when the HVAC
system is not calling for heating or cooling.

In the event an existing thermostat does not have the capability to operate the fan
independently, it is recommended that an AirCycler be installed. An AirCycler
is a device that is wired in parallel with existing thermostat wiring, and can be
programmed to turn on the HVAC system fan for any desired time interval. A built-
in memory chip tracks the time that a fan operates every hour, and energizes the
fan only if normal requirements for heating and air conditioning have not cycled the
fan unit long enough to meet pre-determined air purification requirements.

An AirCycler may be purchased from the following sources:

Your local HVAC wholesaler or contractor

Shelter Supply, Lakeville, MN (1-800-762-8399)

www.AirCycler.com

1.

Never look into a burning ultraviolet lamp without proper eye protection, as
severe eye damage may result.

2.

Always unplug the power cord from the unit when changing the filter or ultra-
violet UVC lamps.

3.

Do not attempt to clean the photo-catalytic honeycomb core with cleaning
solutions. The catalyst is constantly radiated by short wave ultraviolet UVC
light during operation, and is self-cleaning.

C

CO

OS

ST

T  O

OF

F  O

OP

PE

ER

RA

AT

TIIO

ON

N

(Calculations are based on continuous operation, 24 hours per day, 

and an energy consumption of 32.25 kw-hrs per month)

ELECTRICITY COST (per kw-hr)

MONTHLY COST

ANNUAL COST

$0.06

$1.93

$23.16

$0.08

$2.58

$30.96

$0.10

$3.22

$38.64

FAN OPERATING

 PERIOD

AIR CYCLES

 PER HOUR

AIR CYCLES

 PER DAY

10 minutes per hour

0.9

21

20 minutes per hour

1.8

42

30 minutes per hour

2.7

63

40 minutes per hour

3.6

84

50 minutes per hour

4.5

105

60 minutes per hour

5.4

126

O

OP

PE

ER

RA

AT

TIIO

ON

N

S

SA

AF

FE

ET

TY

Y  IIN

NS

ST

TR

RU

UC

CT

TIIO

ON

NS

S

O

OP

PE

ER

RA

AT

TIIO

ON

N

A

AIIR

R  P

PU

UR

RIIF

FIIC

CA

AT

TIIO

ON

N

A

AIIR

R  C

CY

YC

CL

LE

ES

S

(Calculations are based on a floor area of 3,000 sq. ft.)

Summary of Contents for CX3000GS

Page 1: ...ny defect or defects in workmanship or materials which may develop under proper and normal use by repair or by replacement of the defective part or equipment at Vendor s option FOB factory Unless othe...

Page 2: ...RU UC CT TI IO ON NS S Manufacturer Continental Fan Manufacturing Inc Model CX3000GS Ducted Air Purifier Dimensions 21 W x 25 H x 10 D Weight 26 lbs Max Airflow 2 170 cfm Max Air Velocity 625 fpm Powe...

Page 3: ...OR RE E I IN NS ST TA AL LL LA AT TI IO ON N I IN NS ST TA AL LL LA AT TI IO ON N 1 Unscrew the two locking knobs and remove the inner module from the outer case 2 Take care not to bend or distort th...

Page 4: ...o Replace every 12 months o LED service light turns from green to yellow after 11 months and to red after 12 months R RE EP PL LA AC CI IN NG G L LA AM MP PS S 1 Unplug the power cord from the C CX X...

Page 5: ...70 60 50 40 30 20 10 0 2 300 Sq Foot Home 5 0 3 0 1 0 5 3 77 8 93 4 94 1 95 1 Start Finish Time In Hours Parts Per Million CO 1 2 3 4 5 6 7 8 250 225 200 175 150 125 100 75 50 25 0 99 9 99 7 99 5 99 3...

Page 6: ...50 0 25 504 2000 0 35 576 2250 0 42 648 2500 0 55 720 0 3u 0 5u 0 7u 1 0u 5 0u 10u Removal Percentage Particle Size Microns Percent Reduction First Pass 0 20 40 60 80 100 8 P PA AR RT TI IC CL LE E S...

Page 7: ...n the HVAC system is not calling for heating or cooling In the event an existing thermostat does not have the capability to operate the fan independently it is recommended that an AirCycler be install...

Page 8: ...n the HVAC system is not calling for heating or cooling In the event an existing thermostat does not have the capability to operate the fan independently it is recommended that an AirCycler be install...

Page 9: ...50 0 25 504 2000 0 35 576 2250 0 42 648 2500 0 55 720 0 3u 0 5u 0 7u 1 0u 5 0u 10u Removal Percentage Particle Size Microns Percent Reduction First Pass 0 20 40 60 80 100 8 P PA AR RT TI IC CL LE E S...

Page 10: ...70 60 50 40 30 20 10 0 2 300 Sq Foot Home 5 0 3 0 1 0 5 3 77 8 93 4 94 1 95 1 Start Finish Time In Hours Parts Per Million CO 1 2 3 4 5 6 7 8 250 225 200 175 150 125 100 75 50 25 0 99 9 99 7 99 5 99 3...

Page 11: ...o Replace every 12 months o LED service light turns from green to yellow after 11 months and to red after 12 months R RE EP PL LA AC CI IN NG G L LA AM MP PS S 1 Unplug the power cord from the C CX X...

Page 12: ...OR RE E I IN NS ST TA AL LL LA AT TI IO ON N I IN NS ST TA AL LL LA AT TI IO ON N 1 Unscrew the two locking knobs and remove the inner module from the outer case 2 Take care not to bend or distort th...

Page 13: ...RU UC CT TI IO ON NS S Manufacturer Continental Fan Manufacturing Inc Model CX3000GS Ducted Air Purifier Dimensions 21 W x 25 H x 10 D Weight 26 lbs Max Airflow 2 170 cfm Max Air Velocity 625 fpm Powe...

Page 14: ...ast MERV 11 Electrostatic Filter Ultraviolet UVC Lamps Set of 2 1 Year Replacement Parts Kit comprising 2 CX3000 RFGS 1 CX3000 RLGS P PR RO OD DU UC CT T S SP PE EC CI IF FI IC CA AT TI IO ON NS S P P...

Page 15: ...ny defect or defects in workmanship or materials which may develop under proper and normal use by repair or by replacement of the defective part or equipment at Vendor s option FOB factory Unless othe...

Reviews: