background image

Install of The Compact Panel Cassette Type Indoor Unit

6

Sponge(attachment)

Clamp(attachment)

Below 

0.17in (

4mm

)

Clamp

 Drain hose

Sponge (gray)

Fig.7

Drain stepup pipe note 

The install height of the drain raising pipe should less than 

11in (

280mm

)

.

The drain raising pipe should form a right angle with the unit, and distance to unit should not 

beyond 

12in (

300mm

)

Fig.8

Instruction

 The slant gradient of the attached drain hose should be within 

3in (

75mm

)

 so that the

 

drain 

hole doesn’t has to endure the unnecessary outside force.

 Fig.9

 Please install the drain hose according to the following process if several drain hoses join 

together.

Fig.10

(2). Check the smoothness of drain after installation.

 Check the drain state by immitting 600cc water slowly from the outlet vent or test hole.

 Check the drain in the state of refrigerating after installation of the electric circuit.

39-59in

9in (220mm)

11in (280mm)

1

2

in (

30

0mm)

20

in

 (

5

0

0mm

)

20

in

 (

5

0

0mm

)

3

in

 (

75

mm

)

Summary of Contents for GKH(12)BA-D3DNA2A/I

Page 1: ...MULTI DUCTLESS INVERTER HEAT PUMP INSTALLATION MANUAL PANEL CASSETTE TYPE INDOOR UNIT Models GKH 12 BA D3DNA2A I GKH 18 BA D3DNA2A I...

Page 2: ...rating mode of the indoor unit are clash with the operating mode of the outdoor unit the malfunction light will blink after 5s on the indoor unit or remote controller showing that the operation clash...

Page 3: ...the refrigerant pipe 4 2 7 Drainage hose 5 2 8 Electrical wiring 7 2 9 Install the panel 8 3 Constitutes and Names of Parts of Compact Panel Cassette Type Indoor Unit 10 4 Working Temperature Range 1...

Page 4: ...ent Don t spray or smear any oil paint or insecticide on the surface of unit otherwise fire may be leaded 1 Do not refit the conditioner Please contact the agency or prefect ional personnel to repair...

Page 5: ...Select the place where easy drain condensated coagulated water and easy connect with outdoor unit 6 Make sure that there are enough space for care and maintenance Make sure that the weight between the...

Page 6: ...3DNA2A I GKH 18 BA D3DNA2A I The drilling of holes in the ceiling must be done by the professional personnel Ceiling Installation stands for main body of the unit 6in 160 mm Above 0 78in 20mm Fig 3 No...

Page 7: ...break off and tighten the nut on it 6 Backout the install cardboard Fig 4 Note Please do tighten the nuts and bolts to prevent air conditioner break off 2 6 Connection of the refrigerant pipe When co...

Page 8: ...iameter of the drain hose should be equal or bigger than the connection pipes The diameter of polythene pipe Outer diameter 1 25mm Surface thickness 1 16 1 5mm Drain hose should be short and drooping...

Page 9: ...tion The slant gradient of the attached drain hose should be within 3in 75mm so that the drain hole doesn t has to endure the unnecessary outside force Fig 9 Please install the drain hose according to...

Page 10: ...ividually by impact fastener Wiring according to the indoor side circuit diagram Fix the impact fastener after connection Entwine the small sponge on the electric wire do entwine it to prevent condens...

Page 11: ...p on the panel of the indoor unit 2 positions Hang the remaining 2 latches to the hooks on the sides of the indoor unit Be careful not to let the swing motor lead wire get caught in the sealing materi...

Page 12: ...height of the indoor unit As shown in fig 15 If the raising lever and drain hose are not affect can adjust the height of indoor unit by the hole on the corner of panel Gaps are not allowed Fig 15 Afte...

Page 13: ...Constitutes and Names of Parts of Compact Panel Cassette Type Indoor Unit 10 3 Constitutes and Names of Parts of Compact Panel Cassette Type Indoor Unit GKH 12 BA D3DNA2A I GKH 18 BA D3DNA2A I...

Page 14: ...e Outdoor side stae Dry bulb temp F C Wet bulb temp F C Dry bulb temp F C Wet bulb temp F C Rated Cooling 81 27 66 19 95 35 75 24 Max cooling 90 32 73 23 118 48 79 26 Min cooling 70 21 59 15 64 18 Rat...

Page 15: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 MANUFACTURER GREE ELECTRIC APPLIANCES INC OF ZHUHAI www cooperandhunter us...

Reviews: