June 5, 2012
Chadwick Engineering Ltd.
TITAN Trainer Equine Treadmill
Model 1677-2
Publication No 1760-260-R1
Chadwick Engineering Ltd. -
TITAN Trainer
Model 1677-2
Installation – Operation – Maintenance
Page 16 of
33
4.1
Emergency Stop
The
TITAN Trainer
is equipped with an emergency stop mushroom head type pushbutton
that can be used to de-energize power to the belt drive motor and hydraulic power unit (for
incline movements) in the case of an emergency situation. This button is located to the left of
the user touch screen.
4.2
Control Power
The control power must be on to use the trainer. The main screen below shows the
“Power Off” message that appears if the control power is off. (Note: Even with power off, the
Programmable Logic Controller (PLC) and the Main Screen remain powered.) In addition to
the message, the Power On/Off green illuminated pushbutton to the left of the touch screen
will be off (not illuminated).
To turn the control power on, first ensure the emergency stop is not depressed. Press the
green “Power On/Off” pushbutton to the left of the touch screen. The green light on the
pushbutton should illuminate. Likewise the control power can be turned off by pressing the
button a second time. Power cannot be re-applied until 30 seconds after the last power off. If
the power has been turned off within the last 30 seconds and the user attempts to turn the
power on the touch screen will display a wait message with the remaining time left before the
power can be turned on.
Main Screen with Power Off & Wait Messages
4.3
Alarms