background image

CHALLENGE

2800W Blower and Vac

Original Instructions                                                  Model: CEBLV2840

WARNING

 Important-Please read these instructions fully before starting assembly.

These instructions contain important information that will help you get the best from your product, 

ensuring it is assembled correctly and safely. 

If you need help or have damaged or missing parts, call the Customer Helpline on 01904 727508.

SAN NO.: 0321/8AAA/B021

V2:03/21

1 of 21

Please retain for future reference

Summary of Contents for CEBLV2840

Page 1: ...starting assembly These instructions contain important information that will help you get the best from your product ensuring it is assembled correctly and safely If you need help or have damaged or...

Page 2: ...17 Technical data 18 Trouble shooting 20 Guarantee 21 Produced in China Argos Limited 489 499 Avebury Boulevard Milton Keynes MK9 2NW Argos N I Ltd Forestside Shopping Centre Upper Galwally Belfast Un...

Page 3: ...uction manual Keep bystanders away Switch off Remove plug from mains before cleaning or maintenance Disconnect the mains plug if the cord becomes damaged or entangled Do not expose and operate the pro...

Page 4: ...nteed sound power level value in 105 dB A WEEE symbol Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your local authority or...

Page 5: ...nd knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Local regulations can restrict the age of the operator WARN...

Page 6: ...into the air inlet Keep long hair away from the air inlets Operate the machine in a recommended position and only on a firm level surface Do not operate the machine on a paved or gravel surface where...

Page 7: ...and operating the machine inspect for damage replace or repair any damaged parts refer to trouble shooting section check for and tighten any loose parts Do not allow processed material to build up in...

Page 8: ...dual current device RCD with a tripping current of not more than 30 mA If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified person in order to...

Page 9: ...eing used over long periods of time or not adequately managed and properly maintained Injuries and damage to property due to broken application tools or sudden impact of hidden objects during use Dang...

Page 10: ...duct by a person responsible for their safety Children should be supervised to ensure that they do not play with the product This device is intended solely to blow or collect leaves in private gardens...

Page 11: ...Vacuum Blow selector lever 1 PH2 phillips screw driver not supplied Parts Description Tools Needed For Assembly PART LIST 9 Debris collection bag 10 Wheel 11 Upper Vacuum Blower tube A 12 Upper Vacuum...

Page 12: ...ews item14 in two positions 2 Align the vacuum blower tube assembly to the motor unit and insert t hem all the way to the stop Secure the tube and motor unit with shorter crosshead screws longer screw...

Page 13: ...ened with a phillips PH2 head screwdriver not supplied Align the collection bag with the outlet nozzle and insert into place Attach the shoulder strap to the hook place the shoulder strap over the sho...

Page 14: ...supply and switch on NOTE Ensure the Blower Vac tube is fitted correctly and attach the debris collection bag firmly Select either the Vacuum or Blower function using the selector lever A on the side...

Page 15: ...low function using the selector lever on the side of the machine and switch on With the Blower Vac resting on its wheels move it forward directing the nozzle at the debris to be cleared Adjust the spe...

Page 16: ...t above the ground swing the machine from side to side moving forwards and directing the nozzle at the debris to be collected Do not force the nozzle into the debris as this will block the suction tub...

Page 17: ...and Clean the fan with a soft brush ensuring it is free from debris 5 Clean the air vents with a soft brush 6 Refit the tube and collection bag carefully Always store the product in a dry place ensuri...

Page 18: ...Nominal Air flow Blower up to 13 9m3 min Nominal Air flow Vacuum up to 10 1m3 min Air Flow Blow Vacuum Mode 10m3 min Vibration 2 702m s2 K 1 5m s2 Measured sound pressure level LpA Blower 81 06dB A M...

Page 19: ...the basic standards ISO 11094 and EN ISO 3744 The sound intensity level for the operator may exceed 80dB A and ear protection measures are necessary The declared vibration value has been measured in a...

Page 20: ...e works with interruptions Damaged power cable Disconnect from mains electricity Check cord call service helpline Internal loose connection Repair through customer service Defective on off switch Low...

Page 21: ...ations Consequently the guarantee is invalidated if the equipment is used in commercial trade or industrial applications or for other equivalent activities 3 The guarantee is valid for a period of 1 y...