background image

 

 
 

I-HDL106-02.doc   

 

Issue 11                11/05/2020 

 

 

 

 

 

1

 

 

 

 

 

 

                                        IOM 

– HDL106 Luminaire (ATEX & IECEx)

 

 

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 

HDL106 - Luminaires 

ATEX & IECEx 

Important

Please read these instructions carefully before installing or maintaining this equipment. Good 
electrical practices should be followed at all times and this data should be used 
as a guide only. 

 
 
                           
                                           
                               
                         

      

          Weight 6kg 
            
          Windage – 0.045m²                              
                                 

 
 
 
 

Summary of Contents for HDL106 Series

Page 1: ...ION AND MAINTENANCE INSTRUCTIONS HDL106 Luminaires ATEX IECEx Important Please read these instructions carefully before installing or maintaining this equipment Good electrical practices should be fol...

Page 2: ...l unless multiple conductors have been joined in a suitable manner e g two conductors into a single insulated crimped boot lace ferrule 2 Leads connected to the terminals shall be insulated for the ap...

Page 3: ...umen output photometric data can be requested Power Factor 0 9 minimum Over voltage 375V Looping The looping current rating is 12A 4mm terminals are standard Storage Luminaires are to be stored in coo...

Page 4: ...the front cover and then remove the LED array assembly Care must be taken when disconnecting and reconnecting wiring If required contact Chalmit Technical 4 0 Mounting Luminaires should be installed...

Page 5: ...heck condition of enclosure gasket and fastenings Check for any accumulation of moisture Periodic inspection of the enclosure seal should be carried out to ensure that the seal is sound If the luminai...

Page 6: ...I HDL106 02 doc Issue 11 11 05 2020 6 IOM HDL106 Luminaire ATEX IECEx HIGH VOLTAGE...

Page 7: ...I HDL106 02 doc Issue 11 11 05 2020 7 IOM HDL106 Luminaire ATEX IECEx LOW VOLTAGE Note For 24 LED luminaires there will only be one LED array connected to the terminal block...

Page 8: ...l n y a aucun changement qui affecte mat riellement l tat de l volution technologique du produit zur Erf llung der GSGA ist gegeben da keine nderungen erfolgt sind die einen Einfluss auf den technisch...

Page 9: ...ge ich im Namen von Chalmit dass am Tag der Lieferung des Produkts der Produkte zusammen mit dieser Erkl rung das Ger t die Ger te alle technischen und regulativen Anforderungen der oben aufgef hrten...