PREPARATION

SET POWER SUPPLY VOLTAGE

The receiver can be powered with either 24V ac/dc or with 12Vdc. The 
jumper must be in the 24V position for use with 24V, and in 12V position 
for use with 12Vdc. 

The jumper must be set to the proper voltage to 

avoid damage to the receiver.

The receiver is factory set at 24V 

Figure 1.

SET SECURITY MODE 

The Universal Receiver can be used with up to 15 rolling code 
transmitters or passwords in HIGH security mode. Alternately, it can be 
used with up to 31 of any type transmitter in NORMAL security mode, 
including any combination of rolling code, billion code, or dip switch 
remotes.

The jumper must be set at the HIGH position for the receiver to operate in 
HIGH security mode. It must be set at NORMAL position to operate at the 
NORMAL mode 

Figure 2.

When changing from NORMAL to HIGH security mode, any previous 
transmitter codes must be erased. Repeat Steps 2 and 3 on Side 2 to 
reprogram the receiver for each remote control transmitter in use.

The receiver is factory set at HIGH.

The use of 24V with the jumper in 12V position will cause permanent 
damage to the receiver.

FIGURE 1

FIGURE 2

FIGURE 3

To prevent possible SERIOUS INJURY or DEATH from electrocution:
• Be sure power is not connected BEFORE installing the receiver.

To prevent possible SERIOUS INJURY or DEATH from a moving 
gate or garage door:

•  ALWAYS keep remote controls out of reach of children. NEVER 

 permit children to operate, or play with remote control transmitters.

•  Activate gate or door ONLY when it can be seen clearly, is properly 

adjusted, and there are no obstructions to door travel.

•  ALWAYS keep gate or garage door in sight until completely closed. 

NEVER permit anyone to cross path of moving gate or door.

SET OUTPUT DURATION (COMMERCIAL APPLICATIONS ONLY)

For commercial applications, the receiver can be set for either constant or 
momentary closure on the output contacts. Use of constant closure is 
prohibited on residential garage door openers because it overrides the 
safety reversal devices.

With the jumper in the “M” (Momentary) position, the contacts will close 
for 1/4 second regardless of the length of radio transmission. With the 
jumper in “C” (Constant) position, the contacts will stay closed as long as 
the radio continues transmitting 

Figure 3

.

The receiver is factory set at M.

To prevent possible SERIOUS INJURY or DEATH, the use of 
CONSTANT OPERATION on residential openers is PROHIBITED.

M

NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this 
receiver and/or transmitter are prohibited, except for changing the code setting or replacing the 
battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the 
following two conditions: (1) this device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference that may cause undesired operation.

UNIVERSAL RADIO CONTROL 

MODELS 312HMC & 312HM (315 MHz)
MODELS 412HMC & 412HM (390 MHz)

Circuit Board

Power Supply 

Terminals

Jumper

Circuit Board

Power Supply 

Terminals

Jumper

24V POSITION

12V POSITION

Security Mode 

Terminals

Jumper

HIGH 

SECURITY MODE

NORMAL 

SECURITY MODE

Security Mode 

Terminals

Jumper

M

Output Duration 

Terminals

Jumper

CONSTANT
OPERATION

Output Duration 

Terminals

Jumper

MOMENTARY
OPERATION