DIP SETTINGS
1 / 2 Motor
Select if 1 or 2 motors are connected to the control board
OFF:
2 Motors connected
ON:
1 Motor connected
OPEN/STEP
Changes the programming and reaction of the gate on commands.
For the use with loop detectors please refer to the loop detector
instruction
fi
rst.
Step Mode: The gate starts to open if a command is received, next
stop, next closes, next stop, next open…….
OPEN Mode: The gate will not react on a command during the travel
to the gate open position.
OFF:
STEP
ON:
OPEN
LIGHT/SPY
Gate Monitoring / yard Lighting Select if the function is used or leave free.
OFF: LIGHT(yard lighting)
ON: SPY (gate monitoring)
OBSTACLE
Factory-equipped with wire jumper. Disabling increases the
operating power at the control. CAUTION: If the jumper is
disabled, the door system should be secured with additional
safety devices (contact strip, etc.).
LOOP/EDGE
Select for desired device.
OFF:
EDGE
ON:
LOOP
SPEED
Select for the type of motor you intend to use.
OFF:
Slow ART, LYN, SCS, SUB
ON:
Fast LYN, SCS, SUB
RADIO
The DIP “RADIO” is required to program remote controls.
For programming procedure please refer to page 8, section “radio”
OFF:
No programming of remote controls possible
ON:
Programming of remote controls possible
Important: Switch off DIP “RADIO” if not in use!
Wing Delay Adjustment
The delay of one wing is required to open and close the wings correctly
and to operate the wings with a safe distance from each other. A larger
distance may be required when the mechanical installation distances
are different between the wings or wing length is different. The delay
time in opening direction is
fi
xed. The closing is adjustable
Push P3 and P1 together and hold for approx 5 seconds, and count
the number of clicks you hear. The click sound is produced from a
relay (light relay).
1 click = small delay, about 4÷8 seconds (factory default settings)
2 click = medium delay, about 8÷12 seconds
3 click = big delay, about 12÷16 seconds
4 click = total delay, wing 1 will close only when wing 2 is completely closed
Delay in opening direction is always 3 to 5 seconds.
5 click = no delay in opening and closing (wings move simultaneously)
Repeat the procedure if required.
11/16 en
RADIO MODULE
RADIO MODULE
ON
ON
Summary of Contents for ART300 series
Page 23: ...ART 1 ART 2 ART 3 ART 6 ART 7 115 o 90 o 90 o 90 o 115 o 115 o 115 o 90 o 1 A B 2 3 A...
Page 25: ...6 7 8 9 A B 10 11 A B C D...
Page 26: ...ART 6 ART 7 41ABSC 5 41ASWG 454 41AART 63 ART 3AL 41AART 1022SA 41AART 1026SA 13 12...
Page 27: ......
Page 28: ...709446D 2010...
Page 234: ......
Page 235: ......