14
INSTALLATION STEP 9
Electrical Requirements
To avoid installation diffi culties, do not run the operator at
this time.
To reduce the risk of electric shock, your door operator has a
grounding type plug with a third grounding pin. This plug will
only fi t into a grounding type outlet. If the plug doesn't fi t into
the outlet you have, contact a qualifi ed electrician to install the
proper outlet.
If permanent wiring is required by your local code, refer to
the following procedure.
To make a permanent connection through the 7/8" hole in the
top of the motor unit:
1. Remove the motor unit cover screws and set the cover
aside.
2. Remove the attached 3-prong cord.
3. Connect the black (line) wire to the screw on the brass
terminal; the white (neutral) wire to the screw on the silver
terminal; and the ground wire to the green ground screw.
The operator must be grounded.
4. Reinstall the cover.
To avoid installation diffi culties, do not run the operator at
this time.
To prevent possible SERIOUS INJURY or DEATH from
electrocution or fi re:
• Be sure power is NOT connected to the operator, and
disconnect power to circuit BEFORE removing cover
to establish permanent wiring connection.
• Door installation and wiring MUST be in compliance
with ALL local electrical and building codes.
• NEVER use an extension cord, 2-wire adapter, or
change plug in ANY way to make it fi t outlet. Be sure
the operator is grounded.
RIGHT WRONG
PERMANENT WIRING
CONNECTION
Ground
Tab
Black
Wire
Black
Wire
White
Wire
White
Wire
Green
Ground
Screw
Ground
Wire