Rev C
Doc 6001287 (01-20284)
8 of 40
F.
USING MANUAL CONTROLS
Figure 5. Manual Controls, Location and Use.
If necessary, use the manual controls on Manual Input Terminal TB2 (OPEN, CLOSE, and STOP,
as shown in Figure 5), to move the gate arm during system installation.
•
To open the gate:
connect the OPEN and STOP terminals to the COMMON terminal.
•
To close the gate:
connect the CLOSE and STOP terminals to the COMMON terminal.
•
To stop the gate:
disconnect the STOP terminal from the COMMON terminal.
IMPORTANT NOTE
If the STOP terminal is disconnected from the COMMON terminal, the gate is prevented
from moving and no command will affect the gate.
G.
GATE ARM INSTALLATION
Figure 6. Gate Arm Installation.
1. ARM FABRICATION
1. Use 1" x 6" clear pine or redwood (not supplied).
2. Cut arm to the desired length (up to 12 feet), then taper to dimensions shown in Figure 6.
Tapering the arm reduces weight and reduces warping.
3. Using the arm clamp as a template, drill four 1/2" diameter holes in the wide end of the arm.
4. Finish the arm using an exterior grade paint. Add striping with paint or tape.