Rev C
Doc 6001287 (01-20284)
11 of 40
2. RESTRICTED INSTALLATION ADJUSTMENTS
"Right Reverse" Adjustment (R78)
1. Initiate opening the gate.
2. Wait 1 to 2 seconds, then lightly "tug” against the edge of the gate to simulate an obstacle.
3. If the gate does not stop, reclose the gate and adjust the pot slightly counterclockwise.
4. Repeat steps 1-3 until the gate stops when tugged and has the desired sensitivity.
"Left Reverse" Adjustment (R81)
1. Open the gate fully, then initiate closing the gate.
2. Wait 1 to 2 seconds, then lightly "bump" the leading edge of the gate to simulate an obstacle.
3. If the gate does not stop or back up, reopen the gate and adjust the pot slightly
counterclockwise.
4. Repeat steps 1-3 until the gate stops or backs up when bumped and has the desired
sensitivity.
3. INRUSH CURRENT ADJUSTMENT (R119)
1. Turn the pot fully counterclockwise.
2. Initiate opening the gate.
3. If the gate stops due to a fault condition, slightly adjust the pot clockwise.
4. Repeat steps 2 and 3 until the gate cycles without a fault.
5. Open the gate fully, then initiate closing gate.
6. If the gate stops or backs up due to a fault condition, slightly adjust the pot clockwise.
7. Repeat steps 6 and 7 until the gate cycles without a fault and has the desired sensitivity.
K.
POWER FAIL OPERATION OPTION CONNECTION
a)
Power Fail Operation Option Connection
CAUTION
Perform the next step (battery hookup) with care. Interchanging battery wires temporarily opens
the resettable fuse on gate operator board, disabling the power fail option.
To ensure a safe installation, the gate operator is shipped with the battery partially disconnected
from the Power Fail Option electronics. To enable this option:
•
Connect white/red wire of option harness to positive (+) battery terminal.