23
INTRODUCTION
PRE-INSTALL
NETWORK
INSTALL
ACCESS CONTROL
Auto-Call Feature
Disconnect power BEFORE making electrical connections.
The Loop Detector Board
(model LPEXP, not provided) combined with the LOOPDETLM, provides Auto Call
functionality that is available through the auxiliary switch setting. The LPEXP and
LOOPDETLM can be purchased together as a kit (LPEXPKIT). When the loop detects
a vehicle the number programmed into the “Quick call” fi eld in LiftMaster Cloud is
automatically dialed.
1. Secure the Loop Detector Board (model LPEXP) to the standoffs in the CAPXL with
the provided screws.
2. Connect the wire harness from the Loop Detector Board to the Power/Internet Board.
3. Connect the loop wires to the input on the Loop Detector Board.
4. Plug in the loop detector (model LOOPDETLM).
5. Set both switches on the Loop Detector Board to ON (auxiliary setting).
NOTE:
Loop Detector Board not evaluated by UL.
ON
ON
Plug-in Loop Detector
Model LOOPDETLM
Wire Harness
Loop Wiring
LOOP MODE
SW1
SW2
EXIT
Not supported
INTERRUPT
Not supported
SHADOW
Not supported
AUXILIARY
ON
ON
Switches
LOOP DETECTOR BOARD
For LiftMaster Cloud programming please visit www.LiftMasterCloud.com.