E N T R A P M E N T P R O T E C T I O N D E V I C E S
Contact Sensors (Edge Sensor)
NOTE:
When touched, these electrically activated edge sensors immediately signal the gate operator to stop and reverse. Property
owners are obligated to test edges monthly. See Accessories.
Connect all edge sensors to
the sensor connection.
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Locate entrapment protection devices to protect in BOTH the open and close gate cycles.
• Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls.
WARNING
Close
Sensor
on Wall
Open
Sensor
on Wall
Close Sensor on Gate
Open Sensor
on Wall
Open Sensor on Gate
Gate in Open Position
Gate in Open Position
Parallel
Connection