28
S E T T I N G T I M E R ( O N , O F F )
To use the automatic close for the gate system
the timer switch should be put in the
“
ON
”
position.
To use the push close command,
the timer should be
switched to the
“
OFF
”
position.
Push button
once
to open gate,
push button
again to
close gate.
Set Timer
1 to 60 seconds
1.
Turn Master Timer ON.
2.
Turn Second Timer OFF.
3.
Use Timer on Master Board Only.
(1 to 60 seconds)
Master Board
Master Board
Second Board
1.
Turn BOTH timers OFF.
S i n g l e O p e r a t o r
M a s t e r / S e c o n d O p e r a t o r s
w i t h T i m e r s O N
w i t h T i m e r s O F F
Operators need to be connected by
M/S LINK
. See M/S Link.
Master/Second control boards are interchangeable.
NOTE:
If a secondary safety sensor device is
NOT used when the timer is
ON
, the gate
WILL hit a vehicle obstructing the gate path
before reversing during the close cycle.
NOTE:
Push button once to open gate,
push button again to close gate.