A D J U S T I N G R E V E R S I N G S E N S O R ( S )
The level of reverse sensitivity depends on the weight of the gate
and the condition of installation.
Sensor is set too sensitive
= if the gate stops in midcycle or reverses by itself.
Sensor is not set sensitive enough
= if the gate hits an object and does not stop or reverse.
Adjust the “
Reverse Sensor
” on the control board.
Alarm Sensor does not need to be adjusted except where noted below.
Maximum
Sensitivity
Maximum
Sensitivity
Minimum
Sensitivity
Minimum
Sensitivity
D C 2 0 0 0 ™ R e v e r s e S e n s o r
The DC2000™ has a separate reverse sensor that will need to be adjusted. The 120 Vac
operator power needs to be turned off and the DC2000™ should have the “
Charge OK
”
LED
ON
to make the adjustment.