35
J1
J1
J1
J1
J1
J1
J1
J1
J1
J1
J2
J3
J3
J3
J3
J3
J3
J3
J3
J3
J3
J5
J5
J5
J5
J5
J5
J5
J6
J6
J6
J6
J7
J7
J7
J8
J8
J8
J8
J8
J8
J9
J10
J10
J10
J11
J12
J13
W I R I N G T A B L E • S L 3 0 0 0 U L ™
J1
J1
J1
J2
J2
J2
J2
J2
J2
J2
J3
J3
J3
J3
J3
J3
1
2
3
4
5
6
7
8
9
10
10 Pins
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
1
2
3
4
1
2
3
1
2
3
4
5
6
16 Pins
1
2
3
10 Pins
10 Pins
10 Pins
1
2
3
1
2
3
4
5
6
7
1
2
3
4
5
6
Safety Loop
Input Power
N
eutral
N
ot Used
Input Power 120 Vac
Strike Open
Exit Loop
Radio Receiver –
Radio Receiver
Fire Dept Key Switch
Radio Re
Omni Option Board
Limit Switch Red
N
.O.
Motor White
N
ormally Closed (
N
o Wire)
Motor Black
Limit Switch Brown Com
Motor Red
Purple Com
Blue
N
.O.
Limit Switch Yellow Com
Limit Switch Orange
N
.O.
–
Reset Switch, Interlock Red
–
Reset Switch, Interlock Black
–
–
–
UL Alarm Red
UL Alarm Black
Safety Sensor
Safety Sensor
Relay Adapter Red
Relay Adapter White
Relay Adapter Black
Plug-In Exit Loop Wire
Plug-In Exit Loop Wire
Plug-In Safety Loop Wire
Plug-In Safety Loop Wire
N
ot Used
N
ot Used
1 HP Board
G M/S Link
B M/S Link
A M/S Link
N
ot Used
Safety Loop Detector
Exit Loop Detector
G M/S Link (G)
B M/S Link (B)
A M/S Link (A)
Fire Dept. Key Switch (7)
Fire Dept. Key Switch (8)
Strike Open Push Button (9)
Strike Open Push Button (10)
Radio Receiver – (11)
Radio Receiver (12)
Radio Re (13)
N
ot Used
N
ot Used
Safety External Loop Detector (3)
Safety External Loop Detector (4)
Exit External Loop Detector (5)
Exit External Loop Detector (6)
In
In
–
In
In
In
In
In
In
Out
Out
Out
Out
In
Out
In
In
In
In
In
In
In
In
In
In
In
In
In
Out
Out
In
In
In
In
In
In
In
In
In
–
–
–
In/Out
In/Out
In/Out
–
In
In
5 or 0 VDC
0 V
–
120 Vac
5 or 0 VDC
5 or 0 VDC
0 V
0 V
Dry
24 VDC
24 VDC
0 V
0 V
5 or 0 VDC
120 Vac
0 V
5 or 0 VDC
0 V
5 or 0 VDC
0 V
5 or 0 VDC
–
Dry
–
Dry
–
–
–
24 VDC
0 VDC
5 or 0 VDC
0 V
5 or 0 VDC
0 VDC
0 VDC
2 to 10 VDC
2 to 10 VDC
2 to 10 VDC
2 to 10 VDC
–
–
–
0 VDC
5 or 0 VDC
5 or 0 VDC
–
5 or 0 VDC
5 or 0 VDC
0 V
5 or 0 VDC
5 or 0 VDC
Dry
Dry
5 or 0 VDC
0 V
0 V
5 or 0 VDC
24 VDC
–
–
2 to 10 VDC
2 to 10 VDC
2 to 10 VDC
2 to 10 VDC
In/Out
In/Out
In/Out
In
In
In
In
In
In
Out
–
–
In
In
In
In
N
ot Used
Omni Option Board Input
Motor(s),
Limit Switches,
Maglock/Solenoid
Harness
External Loop
Detector Wires,
120 Vac Power,
Radio Receiver,
Strike Open,
Key Switch
Harness
Radio Receiver,
Strike Open Push Button,
Fire Dept Key Switch
Inputs
External Loop
Detector Center,
Safety, Exit Wires
Input
Master/Second Link
Master/Second Link
Input
Plug-In Loop
Detector Inputs
Plug-In Loop
Detector
Loop Wire Inputs
Relay Adapter
Module Input
UL Alarm and
Safety Sensors
Reset Switch and
Interlock Assembly
Input
J #
Direction
OmniControl™ Board
OmniControl™ Surge Suppressor
Level (+/- 10%)
J Pin #
Input Connection
Signal Type
NOTE:
See diagram on previous page.