W I R I N G T A B L E • S L 3 0 0 0 U L 1 H P ™
39
J1
J1
J1
J1
J1
J1
J1
J1
J1
J1
J2
J3
J3
J3
J3
J3
J3
J3
J3
J3
J3
J5
J5
J5
J5
J5
J5
J5
J6
J6
J6
J6
J7
J7
J7
J8
J8
J8
J8
J8
J8
J9
J10
J10
J10
J11
J12
J13
J1
J1
J1
J2
J2
J2
J2
J2
J2
J2
J3
J3
J3
J3
J3
J3
1
2
3
4
5
6
7
8
9
10
10 Pins
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
1
2
3
4
1
2
3
1
2
3
4
5
6
16 Pins
1
2
3
10 Pins
10 Pins
10 Pins
1
2
3
1
2
3
4
5
6
7
1
2
3
4
5
6
J1
J1
J1
J1
J1
J1
1
2
3
4
5
6
Safety Loop
Input Power
N
eutral
N
ot Used
Input Power 120 Vac
Strike Open
Exit Loop
Radio Receiver –
Radio Receiver
Fire Dept Key Switch
Radio Re
Omni Option Board
Limit Switch Red
N
.O.
–
N
ormally Closed (
N
o Wire)
–
Limit Switch Brown Com
–
Purple Com
Blue
N
.O.
Limit Switch Yellow Com
Limit Switch Orange
N
.O.
–
Reset Switch, Interlock Red
–
Reset Switch, Interlock Black
–
–
–
UL Alarm Red
UL Alarm Black
Safety Sensor
Safety Sensor
Relay Adapter Red
Relay Adapter White
Relay Adapter Black
Plug-In Exit Loop Wire
Plug-In Exit Loop Wire
Plug-In Safety Loop Wire
Plug-In Safety Loop Wire
Plug-In Center Loop Wire
Plug-In Center Loop Wire
1 HP Board
G M/S Link
B M/S Link
A M/S Link
N
ot Used
Safety Loop Detector
Exit Loop Detector
G M/S Link (G)
B M/S Link (B)
A M/S Link (A)
Fire Dept. Key Switch (7)
Fire Dept. Key Switch (8)
Strike Open Push Button (9)
Strike Open Push Button (10)
Radio Receiver – (11)
Radio Receiver (12)
Radio Re (13)
N
ot Used
N
ot Used
Safety External Loop Detector (3)
Safety External Loop Detector (4)
Exit External Loop Detector (5)
Exit External Loop Detector (6)
Motor Red
Motor Black
Motor White
N
eutral
–
Motor Black
Motor White
N
eutral
In
In
–
In
In
In
In
In
In
Out
Out
In
–
In
–
In
–
In
In
In
In
In
In
In
In
In
In
In
Out
Out
In
In
In
In
In
In
In
In
In
In
In
In
In/Out
In/Out
In/Out
–
In
In
5 or 0 VDC
0 V
–
120 Vac
5 or 0 VDC
5 or 0 VDC
0 V
0 V
Dry
24 VDC
24 VDC
5 or 0 VDC
–
5 or 0 VDC
–
0 V
–
0 V
5 or 0 VDC
0 V
5 or 0 VDC
–
Dry
–
Dry
–
–
–
24 VDC
0 VDC
5 or 0 VDC
0 V
5 or 0 VDC
0 VDC
0 VDC
2 to 10 VDC
2 to 10 VDC
2 to 10 VDC
2 to 10 VDC
2 to 10 VDC
2 to 10 VDC
120 Vac
0 VDC
5 or 0 VDC
5 or 0 VDC
–
5 or 0 VDC
5 or 0 VDC
0 V
5 or 0 VDC
5 or 0 VDC
Dry
Dry
5 or 0 VDC
0 V
0 V
5 or 0 VDC
24 VDC
–
–
2 to 10 VDC
2 to 10 VDC
2 to 10 VDC
2 to 10 VDC
0 V
120 Vac
0 V
–
120 Vac
0 V
In/Out
In/Out
In/Out
In
In
In
In
In
In
Out
–
–
In
In
In
In
Out
Out
Out
–
Out
Out
1 HP Board Input
Omni Option Board Input
Limit Switches,
Maglock/Solenoid
Harness
External Loop Detector
Wires,
120 Vac Power,
Radio Receiver,
Strike Open,
Key Switch
Harness
Radio Receiver,
Strike Open Push Button,
Fire Dept Key Switch
Inputs
External Loop
Detector Center,
Safety, Exit Wires
Input
Master/Second Link
Master/Second Link
Input
2 Motors Input
Plug-In Loop
Detector Inputs
Plug-In Loop
Detector
Loop Wire Inputs
Relay Adapter
Module Input
UL Alarm and
Safety Sensors
Reset Switch and
Interlock Assembly
Input
J #
Direction
OmniControl™ Board
1 HP Board
Level (+/- 10%)
J Pin #
Input Connection
Signal Type
NOTE:
See diagram on previous page.
OmniControl™ Surge Suppressor