20
D C P O W E R C O N N E C T I O N
To AVOID damaging 34 Vdc plug-in transformer, it MUST be
enclosed in a suitable weatherproof enclosure and provided
with proper weatherproof fixtures.
To AVOID damaging control board, DO NOT use the solar panel
and the plug-in transformer at the same time.
34 Vdc 1.7 A Plug-in Transformer
Polarity does NOT matter.
Battery Connection
Run power wires
in separate water
tight conduit.
(Not provided)
Input power to
transformer,
120 Vac, 60 Hz.
Earth Ground Rod
Highly Recommended!
See page 18
Use 14 gauge / 300 watt direct
burial, landscape lighting wire NOT
to exceed 500 ft. Use 10 gauge wire
up to 1000 ft. (Not provided)
Plug in the transformer and connect the
battery plug into the surge suppressor J1
battery plug. The “Timer” LED will flash
“3 times”.
After that, check the “
Charge OK
” LED......
......it must be “
ON
”.
If the board or charging LEDs are lit, replace
the fuses ONLY with type and sizes specified.
See page 35.
NOTE:
Master/second control board shown
to demonstrate proper conduit arrangement.
The same connection sequence applies to the
single control board.
Master
Second
CAUTION