U L A L A R M C O N N E C T I O N
B U R G L A R A L A R M C O N N E C T I O N S
This UL alarm is required for UL-325. It will go off after
2 consecutive events
on the reverse sensor or UL sensor occur.
The UL alarm will sound for a period of
5 minutes
unless
the Stop/Reset button is pressed or a new command is received by the Strike
Input Connection. The reset button will
shut off
an activated audio alarm and reset the operator to function again. See page 32.
Mount alarm on bottom of control box
to protect it from the weather.
The control board provides a relay with a normally open contact to
interface with a house alarm.
When interfacing with a house burglar alarm you must install
positive stops
at the gate closed position. See page 28.
Connect the alarm plug
to the J4 “Alarm”
connection on the
control board. See
page 15.
Connect the alarm plug
to the J4 “Alarm”
connection on the
control board.
See page 15.
If the audio alarm goes off, always check the gate area for:
• Obstructions in the gate path.
• Damage to the gate and/or gate operator.
House Alarm
(Normally Open) If the gate is forced open without a valid
command, the proximity switch will be activated, causing
the
house alarm
to activate.
Proximity Switch
Control Board Relay
Contact Rating
0.5 Amp - 125 Vac
1 Amp - 24 Vdc
Part #
APRS
Surge Suppressor