L I M I T S W I T C H A D J U S T M E N T S
Remove operator cover and unlock the operator to adjust the gate’s traveling distance with
the limit switches. Loosen the 2 screws of each limit switch armature. Position the
second
limit switches of each armature to stop the gate in the “full open” and “full closed” positions
(See illustration below). Re-tighten armature screws when gate positions are correct.
Replace operator cover with 4 screws when finished adjusting switches.